| Parameter | Value |
|---|---|
| Orderable part number | HC8LP-470-R |
| OCL (open circuit inductance) | 47.9 uH ±20% |
| Irms (DC, 40 °C rise) | 1.8 A |
| Isat (15% rolloff) | 1.7 A |
| Isat2 (30% rolloff) | 3.1 A |
| DCR typical @ +20 °C | 344 mOhm |
| Volt-time rating (V-us) | 20.3 |
| Package | 10.9 x 10.4 mm |
| Height | 3.5 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +155 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4126 |

Drawing reproduced from Eaton Technical Data 4126: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
A powder core with a non-organic binder is a deliberately conservative choice: it trades a little permeability for predictable behaviour at high current and high temperature. The result is an inductor that stays linear enough for a current-mode loop to be designed around it.
With 344 mOhm typical, the I-squared-R loss at the full 1.8 A rating is about 1.11 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.
The saturation rating reads 15% rolloff. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.
Energy storage at the saturation current is around 69.2 uJ, the number that connects the inductance and the current rating into a single transient figure.
The second saturation column, 3.1 A at 30% rolloff, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.
The HC powder family sits at the higher-inductance end of the high-current range: from a fraction of a microhenry up to tens of microhenry, on surface-mount bodies with powder iron cores. Every row carries two saturation columns so the rolloff criterion can be chosen explicitly.
Within the HC8LP family this is value 16 of 16, in a range that runs from 0.17 uH to 47.9 uH.
One step down the table, HC8LP-330-R, sits at 32.1 uH with 2.3 A and 224 mOhm – the lower inductance buys about 0 A of extra current in the same body.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 344 mOhm becomes roughly 527 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: use the 30% rolloff column only if the loop can tolerate the inductance droop; the tighter column keeps more inductance at the cost of a lower usable peak current.
Does the inductance drift with age?
The binder is non-organic and the core is not gapped with adhesive, so thermal aging of the magnetic path is not a mechanism here. The value is stable across thermal cycles.
Is the part shielded?
The winding is enclosed by the powder core, so the external field is small. It is not a closed ferrite shield, but the fringing field is low enough for dense board layouts.
Is the part shielded?
The winding is enclosed by the powder core, so the external field is small. It is not a closed ferrite shield, but the fringing field is low enough for dense board layouts.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd