Eaton HC8LP-470-R 47.9 uH Powder Iron Inductor, 1.8 A
Eaton HC8LP-470-R 47.9 uH Powder Iron Inductor, 1.8 A

Eaton HC8LP-470-R 47.9 uH Powder Iron Inductor, 1.8 A

Share
Eaton HC8LP-470-R: powder iron high-current inductor, 47.9 uH ±20%, 1.8 A Irms, Isat 1.7 A, DCR 344 mOhm, 10.9 x 10.4 mm.
    • Product Details
    • Download

    Eaton HC8LP-470-R 47.9 uH Powder Iron Inductor, 1.8 A

    HC8LP-470-R at a glance: powder iron high-current inductor, 47.9 uH ±20%, 1.8 A Irms, Isat 1.7 A (15% rolloff), DCR 344 mOhm, 10.9 x 10.4 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHC8LP-470-R
    OCL (open circuit inductance)47.9 uH ±20%
    Irms (DC, 40 °C rise)1.8 A
    Isat (15% rolloff)1.7 A
    Isat2 (30% rolloff)3.1 A
    DCR typical @ +20 °C344 mOhm
    Volt-time rating (V-us)20.3
    Package10.9 x 10.4 mm
    Height3.5 mm
    MountingSurface mount
    Operating temperature-40 °C to +155 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4126

    Dimensions and Pad Layout

    HC8LP-470-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4126: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    A powder core with a non-organic binder is a deliberately conservative choice: it trades a little permeability for predictable behaviour at high current and high temperature. The result is an inductor that stays linear enough for a current-mode loop to be designed around it.

    With 344 mOhm typical, the I-squared-R loss at the full 1.8 A rating is about 1.11 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    The saturation rating reads 15% rolloff. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    Energy storage at the saturation current is around 69.2 uJ, the number that connects the inductance and the current rating into a single transient figure.

    The second saturation column, 3.1 A at 30% rolloff, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.

    Positioning in the Range

    The HC powder family sits at the higher-inductance end of the high-current range: from a fraction of a microhenry up to tens of microhenry, on surface-mount bodies with powder iron cores. Every row carries two saturation columns so the rolloff criterion can be chosen explicitly.

    Within the HC8LP family this is value 16 of 16, in a range that runs from 0.17 uH to 47.9 uH.

    One step down the table, HC8LP-330-R, sits at 32.1 uH with 2.3 A and 224 mOhm – the lower inductance buys about 0 A of extra current in the same body.

    • Core material: powder iron core, 10.9 x 10.4 mm body at 3.5 mm.
    • Typical applications: multi-phase regulators; voltage regulator modules (vrms); distributed power systems dc-dc converters; notebook and laptop regulators; desktop and server vrms and evrds; point-of-load (pol) modules.
    • The two saturation columns are different criteria, not two measurements of the same thing. Pick the rolloff you can tolerate in the application and stay with that column.

    Sizing and Layout Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 344 mOhm becomes roughly 527 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: use the 30% rolloff column only if the loop can tolerate the inductance droop; the tighter column keeps more inductance at the cost of a lower usable peak current.

    • Confirm the part marking is visible after placement for traceability.
    • Check the volt-time rating against the applied V-us at the switching frequency.
    • Confirm the part marking is visible after placement for traceability.

    Frequently Asked Questions

    Does the inductance drift with age?
    The binder is non-organic and the core is not gapped with adhesive, so thermal aging of the magnetic path is not a mechanism here. The value is stable across thermal cycles.

    Is the part shielded?
    The winding is enclosed by the powder core, so the external field is small. It is not a closed ferrite shield, but the fringing field is low enough for dense board layouts.

    Is the part shielded?
    The winding is enclosed by the powder core, so the external field is small. It is not a closed ferrite shield, but the fringing field is low enough for dense board layouts.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products