Eaton HC8LP-4R5-R 4.57 uH Powder Iron Inductor, 6.5 A
Eaton HC8LP-4R5-R 4.57 uH Powder Iron Inductor, 6.5 A

Eaton HC8LP-4R5-R 4.57 uH Powder Iron Inductor, 6.5 A

Share
Eaton HC8LP-4R5-R: powder iron high-current inductor, 4.57 uH ±20%, 6.5 A Irms, Isat 5.6 A, DCR 27.6 mOhm, 10.9 x 10.4 mm.
    • Product Details
    • Download

    Eaton HC8LP-4R5-R 4.57 uH Powder Iron Inductor, 6.5 A

    HC8LP-4R5-R at a glance: powder iron high-current inductor, 4.57 uH ±20%, 6.5 A Irms, Isat 5.6 A (15% rolloff), DCR 27.6 mOhm, 10.9 x 10.4 mm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberHC8LP-4R5-R
    OCL (open circuit inductance)4.57 uH ±20%
    Irms (DC, 40 °C rise)6.5 A
    Isat (15% rolloff)5.6 A
    Isat2 (30% rolloff)10 A
    DCR typical @ +20 °C27.6 mOhm
    Volt-time rating (V-us)6.3
    Package10.9 x 10.4 mm
    Height3.5 mm
    MountingSurface mount
    Operating temperature-40 °C to +155 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4126

    Dimensions and Pad Layout

    HC8LP-4R5-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4126: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    This is a surface-mount inductor on a distributed air gap: the powder core spreads the gap through the whole volume, which is why the part tolerates large DC bias without a cliff in the inductance curve, and why it is used on multiphase rails where the inductors share current.

    With 27.6 mOhm typical, the I-squared-R loss at the full 6.5 A rating is about 1.17 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    Saturation is quoted as 15% rolloff. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.

    Energy storage at the saturation current is around 71.7 uJ, the number that connects the inductance and the current rating into a single transient figure.

    The second saturation column, 10 A at 30% rolloff, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.

    Series Positioning

    The HC powder family sits at the higher-inductance end of the high-current range: from a fraction of a microhenry up to tens of microhenry, on surface-mount bodies with powder iron cores. Every row carries two saturation columns so the rolloff criterion can be chosen explicitly.

    In the HC8LP line-up this part is number 8 of 16 by inductance, between 0.17 uH and 47.9 uH.

    One step down the table, HC8LP-3R5-R, sits at 3.56 uH with 6.9 A and 24.5 mOhm – the lower inductance buys about 1.4 A of extra current in the same body.

    • Core material: powder iron core, 10.9 x 10.4 mm body at 3.5 mm.
    • Typical applications: multi-phase regulators; voltage regulator modules (vrms); distributed power systems dc-dc converters; notebook and laptop regulators; desktop and server vrms and evrds; point-of-load (pol) modules.
    • The two saturation columns are different criteria, not two measurements of the same thing. Pick the rolloff you can tolerate in the application and stay with that column.

    Putting It to Work

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 27.6 mOhm becomes roughly 42.2 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: use the 30% rolloff column only if the loop can tolerate the inductance droop; the tighter column keeps more inductance at the cost of a lower usable peak current.

    • Use the inductance-versus-DC-bias curve for the ripple calculation, not OCL.
    • Check the volt-time rating against the applied V-us at the switching frequency.
    • Check the volt-time rating against the applied V-us at the switching frequency.

    Frequently Asked Questions

    Which saturation column should I design to?
    The one that matches the inductance droop your loop can tolerate. The 30 % column gives a higher usable peak current; the tighter column keeps more inductance at the cost of headroom.

    Is the part shielded?
    The winding is enclosed by the powder core, so the external field is small. It is not a closed ferrite shield, but the fringing field is low enough for dense board layouts.

    Is the part shielded?
    The winding is enclosed by the powder core, so the external field is small. It is not a closed ferrite shield, but the fringing field is low enough for dense board layouts.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products