| Parameter | Value |
|---|---|
| Orderable part number | HC8LP-6R9-R |
| OCL (open circuit inductance) | 6.98 uH ±20% |
| Irms (DC, 40 °C rise) | 5.2 A |
| Isat (15% rolloff) | 4.6 A |
| Isat2 (30% rolloff) | 8.1 A |
| DCR typical @ +20 °C | 42.8 mOhm |
| Volt-time rating (V-us) | 7.8 |
| Package | 10.9 x 10.4 mm |
| Height | 3.5 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +155 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4126 |

Drawing reproduced from Eaton Technical Data 4126: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
This is a surface-mount inductor on a distributed air gap: the powder core spreads the gap through the whole volume, which is why the part tolerates large DC bias without a cliff in the inductance curve, and why it is used on multiphase rails where the inductors share current.
Copper loss at the rated current works out to roughly 1.16 W from a typical DCR of 42.8 mOhm at 5.2 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
The Isat column is 15% rolloff. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.
The core stores roughly 73.8 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.
The second saturation column, 8.1 A at 30% rolloff, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.
The HC powder family sits at the higher-inductance end of the high-current range: from a fraction of a microhenry up to tens of microhenry, on surface-mount bodies with powder iron cores. Every row carries two saturation columns so the rolloff criterion can be chosen explicitly.
Within the HC8LP family this is value 10 of 16, in a range that runs from 0.17 uH to 47.9 uH.
The next value up in the same family, HC8LP-8R2-R, gives 8.37 uH at 4.5 A and DCR 58 mOhm: the extra inductance costs about 1 A of rated current.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 42.8 mOhm becomes roughly 65.5 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: use the 30% rolloff column only if the loop can tolerate the inductance droop; the tighter column keeps more inductance at the cost of a lower usable peak current.
How do I estimate the inductance at my operating current?
Read it off the inductance-versus-DC-bias curve in the data sheet at the actual bias. The curve, not the OCL value, is what sets the ripple at load.
How do I estimate the inductance at my operating current?
Read it off the inductance-versus-DC-bias curve in the data sheet at the actual bias. The curve, not the OCL value, is what sets the ripple at load.
What is soft saturation?
The inductance falls gradually as current rises instead of collapsing at a threshold. A powder core with a distributed gap behaves this way, which keeps the converter stable through a load transient.