Eaton HC8LP-R15-R 0.170 uH SMD Power Inductor, 7.8 V-us
Eaton HC8LP-R15-R 0.170 uH SMD Power Inductor, 7.8 V-us

Eaton HC8LP-R15-R 0.170 uH SMD Power Inductor, 7.8 V-us

Share
Eaton HC8LP-R15-R: powder iron high-current inductor, 0.170 uH ±20%, 29 A Irms, Isat 31 A, DCR 1.4 mOhm, 10.9 x 10.4 mm.
    • Product Details
    • Download

    Eaton HC8LP-R15-R 0.170 uH SMD Power Inductor, 7.8 V-us

    HC8LP-R15-R at a glance: powder iron high-current inductor, 0.170 uH ±20%, 29 A Irms, Isat 31 A (15% rolloff), DCR 1.4 mOhm, 10.9 x 10.4 mm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberHC8LP-R15-R
    OCL (open circuit inductance)0.170 uH ±20%
    Irms (DC, 40 °C rise)29 A
    Isat (15% rolloff)31 A
    Isat2 (30% rolloff)56 A
    DCR typical @ +20 °C1.4 mOhm
    Volt-time rating (V-us)7.8
    Package10.9 x 10.4 mm
    Height3.5 mm
    MountingSurface mount
    Operating temperature-40 °C to +155 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4126

    Mechanical Drawing

    HC8LP-R15-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4126: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    A powder core with a non-organic binder is a deliberately conservative choice: it trades a little permeability for predictable behaviour at high current and high temperature. The result is an inductor that stays linear enough for a current-mode loop to be designed around it.

    Copper loss at the rated current works out to roughly 1.18 W from a typical DCR of 1.4 mOhm at 29 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    The Isat column is 15% rolloff. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    Stored energy at Isat is about 81.7 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.

    The second saturation column, 56 A at 30% rolloff, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.

    What This Family Is For

    The HC powder family sits at the higher-inductance end of the high-current range: from a fraction of a microhenry up to tens of microhenry, on surface-mount bodies with powder iron cores. Every row carries two saturation columns so the rolloff criterion can be chosen explicitly.

    Within the HC8LP family this is value 1 of 16, in a range that runs from 0.17 uH to 47.9 uH.

    Compared with its neighbours in the table, HC8LP-R39-R trades 0 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: powder iron core, 10.9 x 10.4 mm body at 3.5 mm.
    • Typical applications: multi-phase regulators; voltage regulator modules (vrms); distributed power systems dc-dc converters; notebook and laptop regulators; desktop and server vrms and evrds; point-of-load (pol) modules.
    • The two saturation columns are different criteria, not two measurements of the same thing. Pick the rolloff you can tolerate in the application and stay with that column.

    Sizing It Into a Design

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 1.4 mOhm becomes roughly 2.14 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: use the 30% rolloff column only if the loop can tolerate the inductance droop; the tighter column keeps more inductance at the cost of a lower usable peak current.

    • Use the inductance-versus-DC-bias curve for the ripple calculation, not OCL.
    • Compare the two saturation columns before fixing the current limit in the controller.
    • Check that the inductance at the working DC bias still meets the ripple target.

    Frequently Asked Questions

    Is the part shielded?
    The winding is enclosed by the powder core, so the external field is small. It is not a closed ferrite shield, but the fringing field is low enough for dense board layouts.

    What is soft saturation?
    The inductance falls gradually as current rises instead of collapsing at a threshold. A powder core with a distributed gap behaves this way, which keeps the converter stable through a load transient.

    How do I estimate the inductance at my operating current?
    Read it off the inductance-versus-DC-bias curve in the data sheet at the actual bias. The curve, not the OCL value, is what sets the ripple at load.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products