| Parameter | Value |
|---|---|
| Orderable part number | HC9-330-R |
| OCL (open circuit inductance) | 34.5 uH ±15% |
| Irms (DC, 40 °C rise) | 4.42 A |
| Isat (20% rolloff) | 4.8 A |
| Isat2 (30% rolloff) | 7 A |
| DCR typical @ +20 °C | 48.8 mOhm |
| Volt-time rating (V-us) | 37.3 |
| Package | 13.1 x 14.1 mm |
| Height | 7.5 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +155 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data DS4312 |

Drawing reproduced from Eaton Technical Data DS4312: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
This is a surface-mount inductor on a distributed air gap: the powder core spreads the gap through the whole volume, which is why the part tolerates large DC bias without a cliff in the inductance curve, and why it is used on multiphase rails where the inductors share current.
At the rated 4.42 A the winding dissipates about 0.953 W in copper alone, using the typical DCR of 48.8 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.
The saturation rating reads 20% rolloff. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.
Energy storage at the saturation current is around 397 uJ, the number that connects the inductance and the current rating into a single transient figure.
The second saturation column, 7 A at 30% rolloff, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.
The HC powder family sits at the higher-inductance end of the high-current range: from a fraction of a microhenry up to tens of microhenry, on surface-mount bodies with powder iron cores. Every row carries two saturation columns so the rolloff criterion can be chosen explicitly.
Of the 12 values listed for HC9, this is the 11th, in a family covering 0.218 uH to 49.2 uH.
One step down the table, HC9-220-R, sits at 22.4 uH with 6.3 A and 25.7 mOhm – the lower inductance buys about 2.65 A of extra current in the same body.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 48.8 mOhm becomes roughly 74.7 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: use the 30% rolloff column only if the loop can tolerate the inductance droop; the tighter column keeps more inductance at the cost of a lower usable peak current.
What is soft saturation?
The inductance falls gradually as current rises instead of collapsing at a threshold. A powder core with a distributed gap behaves this way, which keeps the converter stable through a load transient.
Does the inductance drift with age?
The binder is non-organic and the core is not gapped with adhesive, so thermal aging of the magnetic path is not a mechanism here. The value is stable across thermal cycles.
Is the part shielded?
The winding is enclosed by the powder core, so the external field is small. It is not a closed ferrite shield, but the fringing field is low enough for dense board layouts.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd