Eaton HCF1007-100-R: ferrite high-current power inductor, 10.0 uH ±20%, 9.4 A Irms, Isat 5.3 A, DCR 8.65 mOhm, 10.3 x 8.1 mm.
    • Product Details
    • Download

    Eaton HCF1007-100-R Ferrite Inductor 10.0 uH, Isat 5.3 A

    HCF1007-100-R at a glance: ferrite high-current power inductor, 10.0 uH ±20%, 9.4 A Irms, Isat 5.3 A (20% rolloff @ +25 °C), DCR 8.65 mOhm, 10.3 x 8.1 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHCF1007-100-R
    OCL (open circuit inductance)10.0 uH ±20%
    FLL minimum, at Isat7.2 uH
    Irms (DC, 40 °C rise)9.4 A
    Isat (20% rolloff @ +25 °C)5.3 A
    Isat2 (20% rolloff @ +125 °C)4.2 A
    DCR typical @ +20 °C8.65 mOhm
    K-factor (Bp-p = K x L x dI)70, Bp-p in Gauss
    Package10.3 x 8.1 mm
    Height6.65 mm
    MountingSurface mount
    Operating temperature-40 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4361

    Dimensions and Pad Layout

    HCF1007-100-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4361: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    Reading the Data Sheet

    Ferrite, tight DCR, high current: the family is aimed at switching converters where the inductor value has to be known accurately and the loss budget is tight. The data sheet quotes OCL, full-load inductance and saturation current separately so the three can be traded against each other.

    The DCR figure of 8.65 mOhm is what sets the efficiency: at 9.4 A the winding drops about 0.081 mV and dissipates 0.764 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.

    Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.

    Energy storage at the saturation current is around 140 uJ, the number that connects the inductance and the current rating into a single transient figure.

    The K-factor of 70 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 700 Gauss of Bp-p, the figure the core-loss curve is plotted against.

    The second saturation column, 4.2 A at 20% rolloff @ +125 °C, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.

    Series Positioning

    The HCF family is the ferrite option in the high-current range: lower core loss than a powder part at high frequency, with saturation current quoted at both +25 °C and +125 °C. It is the family for converters that run fast and hot.

    Within the HCF1007 family this is value 12 of 12, in a range that runs from 0.3 uH to 10 uH.

    The next value up in the same family, HCF1007-6R8-R, gives 6.8 uH at 9.4 A and DCR 8.65 mOhm: the extra inductance costs about 0 A of rated current.

    • Core material: ferrite core, 10.3 x 8.1 mm body at 6.65 mm.
    • Typical applications: voltage regulator modules (vrm); high current dc-dc converters; multi-phase buck regulators; servers and data networking; point-of-load modules.
    • Ferrite loses saturation margin as it heats. The +125 °C Isat column is the one that governs a hot design; the +25 °C figure is the optimistic one.

    Sizing and Layout Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 8.65 mOhm becomes roughly 12.2 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the full-load inductance (FLL) is the value to use for ripple at rated current. OCL is the small-signal number; FLL is what the converter actually sees under load.

    • Use the +125 °C saturation column for the current limit in the controller.
    • Calculate ripple with FLL, not OCL: the loaded inductance is what the converter sees.
    • Check the full-load inductance against the ripple target at maximum load.

    Frequently Asked Questions

    How is the K-factor used?
    Multiply K by the inductance in microhenry and by the peak-to-peak ripple in amps to get the flux swing the core sees. Read the core-loss curve at that amplitude and at your switching frequency.

    Is a three-terminal part a drop-in for a two-terminal one?
    No. The third terminal is part of the construction and changes the pad layout and the current path, so the board needs the matching footprint.

    What is the difference between OCL and FLL?
    OCL is the open-circuit inductance measured at low signal. FLL is the inductance remaining at the saturation current. Ripple at full load should be calculated with FLL, not OCL.