| Parameter | Value |
|---|---|
| Orderable part number | HCF1007-1R0-R |
| OCL (open circuit inductance) | 1.0 uH ±20% |
| FLL minimum, at Isat | 0.72 uH |
| Irms (DC, 40 °C rise) | 16 A |
| Isat (20% rolloff @ +25 °C) | 26 A |
| Isat2 (20% rolloff @ +125 °C) | 21 A |
| DCR typical @ +20 °C | 2.65 mOhm |
| K-factor (Bp-p = K x L x dI) | 140, Bp-p in Gauss |
| Package | 10.3 x 8.1 mm |
| Height | 6.65 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4361 |

Drawing reproduced from Eaton Technical Data 4361: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
The core is ferrite, and the family is characterised at two temperatures: the saturation current is quoted at +25 °C and again at +125 °C. That second column is the one that decides whether the part survives a hot corner, because ferrite loses saturation margin as it heats.
Copper loss at the rated current works out to roughly 0.678 W from a typical DCR of 2.65 mOhm at 16 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.
The core stores roughly 338 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.
K-factor 140 means the flux swing is about 140 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.
The second saturation column, 21 A at 20% rolloff @ +125 °C, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.
The HCF family is the ferrite option in the high-current range: lower core loss than a powder part at high frequency, with saturation current quoted at both +25 °C and +125 °C. It is the family for converters that run fast and hot.
Of the 12 values listed for HCF1007, this is the 5th, in a family covering 0.3 uH to 10 uH.
Compared with its neighbours in the table, HCF1007-1R5-R trades 13 A of rated current for the next inductance step, which is the usual compromise in this family.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 2.65 mOhm becomes roughly 3.74 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the full-load inductance (FLL) is the value to use for ripple at rated current. OCL is the small-signal number; FLL is what the converter actually sees under load.
Is a three-terminal part a drop-in for a two-terminal one?
No. The third terminal is part of the construction and changes the pad layout and the current path, so the board needs the matching footprint.
Why are there two saturation currents?
Ferrite loses saturation flux density as it heats. The +25 °C column describes a bench measurement; the +125 °C column describes the part under load in a hot enclosure, which is the one that governs the design.
What happens above the self-resonant frequency?
The part becomes capacitive and no longer behaves as an inductor. Keep the switching frequency and the harmonics that carry energy comfortably below SRF where one is quoted.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd