Eaton HCF1007-1R0-R 1.0 uH High-Current Inductor 2.65 mOhm
Eaton HCF1007-1R0-R 1.0 uH High-Current Inductor 2.65 mOhm

Eaton HCF1007-1R0-R 1.0 uH High-Current Inductor 2.65 mOhm

Share
Eaton HCF1007-1R0-R: ferrite high-current power inductor, 1.0 uH ±20%, 16 A Irms, Isat 26 A, DCR 2.65 mOhm, 10.3 x 8.1 mm.
    • Product Details
    • Download

    Eaton HCF1007-1R0-R 1.0 uH High-Current Inductor 2.65 mOhm

    HCF1007-1R0-R at a glance: ferrite high-current power inductor, 1.0 uH ±20%, 16 A Irms, Isat 26 A (20% rolloff @ +25 °C), DCR 2.65 mOhm, 10.3 x 8.1 mm.

    Specification Table

    ParameterValue
    Orderable part numberHCF1007-1R0-R
    OCL (open circuit inductance)1.0 uH ±20%
    FLL minimum, at Isat0.72 uH
    Irms (DC, 40 °C rise)16 A
    Isat (20% rolloff @ +25 °C)26 A
    Isat2 (20% rolloff @ +125 °C)21 A
    DCR typical @ +20 °C2.65 mOhm
    K-factor (Bp-p = K x L x dI)140, Bp-p in Gauss
    Package10.3 x 8.1 mm
    Height6.65 mm
    MountingSurface mount
    Operating temperature-40 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4361

    Mechanical Drawing

    HCF1007-1R0-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4361: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    The core is ferrite, and the family is characterised at two temperatures: the saturation current is quoted at +25 °C and again at +125 °C. That second column is the one that decides whether the part survives a hot corner, because ferrite loses saturation margin as it heats.

    Copper loss at the rated current works out to roughly 0.678 W from a typical DCR of 2.65 mOhm at 16 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    The core stores roughly 338 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.

    K-factor 140 means the flux swing is about 140 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    The second saturation column, 21 A at 20% rolloff @ +125 °C, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.

    What This Family Is For

    The HCF family is the ferrite option in the high-current range: lower core loss than a powder part at high frequency, with saturation current quoted at both +25 °C and +125 °C. It is the family for converters that run fast and hot.

    Of the 12 values listed for HCF1007, this is the 5th, in a family covering 0.3 uH to 10 uH.

    Compared with its neighbours in the table, HCF1007-1R5-R trades 13 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: ferrite core, 10.3 x 8.1 mm body at 6.65 mm.
    • Typical applications: voltage regulator modules (vrm); high current dc-dc converters; multi-phase buck regulators; servers and data networking; point-of-load modules.
    • Ferrite loses saturation margin as it heats. The +125 °C Isat column is the one that governs a hot design; the +25 °C figure is the optimistic one.

    Sizing and Layout Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 2.65 mOhm becomes roughly 3.74 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the full-load inductance (FLL) is the value to use for ripple at rated current. OCL is the small-signal number; FLL is what the converter actually sees under load.

    • Check the full-load inductance against the ripple target at maximum load.
    • Use the +125 °C saturation column for the current limit in the controller.
    • Check saturation at the +125 °C column when the enclosure runs hot.

    Frequently Asked Questions

    Is a three-terminal part a drop-in for a two-terminal one?
    No. The third terminal is part of the construction and changes the pad layout and the current path, so the board needs the matching footprint.

    Why are there two saturation currents?
    Ferrite loses saturation flux density as it heats. The +25 °C column describes a bench measurement; the +125 °C column describes the part under load in a hot enclosure, which is the one that governs the design.

    What happens above the self-resonant frequency?
    The part becomes capacitive and no longer behaves as an inductor. Keep the switching frequency and the harmonics that carry energy comfortably below SRF where one is quoted.