Eaton HCF1007-1R5-R 1.5 uH Ferrite Power Inductor, 13 A
Eaton HCF1007-1R5-R 1.5 uH Ferrite Power Inductor, 13 A

Eaton HCF1007-1R5-R 1.5 uH Ferrite Power Inductor, 13 A

Share
Eaton HCF1007-1R5-R: ferrite high-current power inductor, 1.5 uH ±20%, 13 A Irms, Isat 22 A, DCR 4.15 mOhm, 10.3 x 8.1 mm.
    • Product Details
    • Download

    Eaton HCF1007-1R5-R 1.5 uH Ferrite Power Inductor, 13 A

    HCF1007-1R5-R at a glance: ferrite high-current power inductor, 1.5 uH ±20%, 13 A Irms, Isat 22 A (20% rolloff @ +25 °C), DCR 4.15 mOhm, 10.3 x 8.1 mm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberHCF1007-1R5-R
    OCL (open circuit inductance)1.5 uH ±20%
    FLL minimum, at Isat1.08 uH
    Irms (DC, 40 °C rise)13 A
    Isat (20% rolloff @ +25 °C)22 A
    Isat2 (20% rolloff @ +125 °C)17 A
    DCR typical @ +20 °C4.15 mOhm
    K-factor (Bp-p = K x L x dI)112, Bp-p in Gauss
    Package10.3 x 8.1 mm
    Height6.65 mm
    MountingSurface mount
    Operating temperature-40 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4361

    Dimensions and Pad Layout

    HCF1007-1R5-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4361: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    Reading the Data Sheet

    This inductor uses a ferrite core with a winding arranged to present a high DC bias resistance. In practice that means the inductance holds up further into the load range than a plain ferrite part of the same size, and the part runs on converters that need low core loss rather than the soft saturation of a powder core.

    The DCR figure of 4.15 mOhm is what sets the efficiency: at 13 A the winding drops about 0.054 mV and dissipates 0.701 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.

    The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    Energy storage at the saturation current is around 363 uJ, the number that connects the inductance and the current rating into a single transient figure.

    The K-factor of 112 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 168 Gauss of Bp-p, the figure the core-loss curve is plotted against.

    The second saturation column, 17 A at 20% rolloff @ +125 °C, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.

    Positioning in the Range

    The HCF family is the ferrite option in the high-current range: lower core loss than a powder part at high frequency, with saturation current quoted at both +25 °C and +125 °C. It is the family for converters that run fast and hot.

    The HCF1007 family spans 0.3 uH to 10 uH; this row sits at position 6 of 12.

    One step down the table, HCF1007-1R0-R, sits at 1.0 uH with 16 A and 2.65 mOhm – the lower inductance buys about 5.3 A of extra current in the same body.

    • Core material: ferrite core, 10.3 x 8.1 mm body at 6.65 mm.
    • Typical applications: voltage regulator modules (vrm); high current dc-dc converters; multi-phase buck regulators; servers and data networking; point-of-load modules.
    • Ferrite loses saturation margin as it heats. The +125 °C Isat column is the one that governs a hot design; the +25 °C figure is the optimistic one.

    Putting It to Work

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 4.15 mOhm becomes roughly 5.86 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the full-load inductance (FLL) is the value to use for ripple at rated current. OCL is the small-signal number; FLL is what the converter actually sees under load.

    • Check saturation at the +125 °C column when the enclosure runs hot.
    • Check saturation at the +125 °C column when the enclosure runs hot.
    • Check saturation at the +125 °C column when the enclosure runs hot.

    Frequently Asked Questions

    Is a three-terminal part a drop-in for a two-terminal one?
    No. The third terminal is part of the construction and changes the pad layout and the current path, so the board needs the matching footprint.

    Is this part suitable for current sensing?
    The family includes parts with tight DCR tolerance for exactly that purpose, but the tolerance is quoted at +20 °C. Copper drift with temperature has to be compensated in the sensing circuit.

    What is the difference between OCL and FLL?
    OCL is the open-circuit inductance measured at low signal. FLL is the inductance remaining at the saturation current. Ripple at full load should be calculated with FLL, not OCL.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd