Eaton HCF1007-3R3-R Ferrite Inductor 3.3 uH, Isat 14.5 A
Eaton HCF1007-3R3-R Ferrite Inductor 3.3 uH, Isat 14.5 A

Eaton HCF1007-3R3-R Ferrite Inductor 3.3 uH, Isat 14.5 A

Share
Eaton HCF1007-3R3-R: ferrite high-current power inductor, 3.3 uH ±20%, 10 A Irms, Isat 14.5 A, DCR 7.5 mOhm, 10.3 x 8.1 mm.
    • Product Details
    • Download

    Eaton HCF1007-3R3-R Ferrite Inductor 3.3 uH, Isat 14.5 A

    HCF1007-3R3-R at a glance: ferrite high-current power inductor, 3.3 uH ±20%, 10 A Irms, Isat 14.5 A (20% rolloff @ +25 °C), DCR 7.5 mOhm, 10.3 x 8.1 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHCF1007-3R3-R
    OCL (open circuit inductance)3.3 uH ±20%
    FLL minimum, at Isat2.37 uH
    Irms (DC, 40 °C rise)10 A
    Isat (20% rolloff @ +25 °C)14.5 A
    Isat2 (20% rolloff @ +125 °C)11 A
    DCR typical @ +20 °C7.5 mOhm
    K-factor (Bp-p = K x L x dI)80, Bp-p in Gauss
    Package10.3 x 8.1 mm
    Height6.65 mm
    MountingSurface mount
    Operating temperature-40 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4361

    Mechanical Drawing

    HCF1007-3R3-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4361: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    Reading the Data Sheet

    Ferrite, tight DCR, high current: the family is aimed at switching converters where the inductor value has to be known accurately and the loss budget is tight. The data sheet quotes OCL, full-load inductance and saturation current separately so the three can be traded against each other.

    The DCR figure of 7.5 mOhm is what sets the efficiency: at 10 A the winding drops about 0.075 mV and dissipates 0.75 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.

    Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.

    Stored energy at Isat is about 347 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.

    K-factor 80 means the flux swing is about 264 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    The second saturation column, 11 A at 20% rolloff @ +125 °C, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.

    Series Positioning

    The HCF family is the ferrite option in the high-current range: lower core loss than a powder part at high frequency, with saturation current quoted at both +25 °C and +125 °C. It is the family for converters that run fast and hot.

    In the HCF1007 line-up this part is number 8 of 12 by inductance, between 0.3 uH and 10 uH.

    The next value up in the same family, HCF1007-4R7-R, gives 4.7 uH at 9.4 A and DCR 8.65 mOhm: the extra inductance costs about 1.3 A of rated current.

    • Core material: ferrite core, 10.3 x 8.1 mm body at 6.65 mm.
    • Typical applications: voltage regulator modules (vrm); high current dc-dc converters; multi-phase buck regulators; servers and data networking; point-of-load modules.
    • Ferrite loses saturation margin as it heats. The +125 °C Isat column is the one that governs a hot design; the +25 °C figure is the optimistic one.

    Design Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 7.5 mOhm becomes roughly 10.6 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the full-load inductance (FLL) is the value to use for ripple at rated current. OCL is the small-signal number; FLL is what the converter actually sees under load.

    • Calculate ripple with FLL, not OCL: the loaded inductance is what the converter sees.
    • Confirm the terminal arrangement matches the pad layout for three-terminal parts.
    • Read the core-loss curve at the Bp-p implied by the K-factor and the ripple.

    Frequently Asked Questions

    Why are there two saturation currents?
    Ferrite loses saturation flux density as it heats. The +25 °C column describes a bench measurement; the +125 °C column describes the part under load in a hot enclosure, which is the one that governs the design.

    Is this part suitable for current sensing?
    The family includes parts with tight DCR tolerance for exactly that purpose, but the tolerance is quoted at +20 °C. Copper drift with temperature has to be compensated in the sensing circuit.

    What happens above the self-resonant frequency?
    The part becomes capacitive and no longer behaves as an inductor. Keep the switching frequency and the harmonics that carry energy comfortably below SRF where one is quoted.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products