Eaton HCF1007-4R7-R 4.7 uH High-Current Inductor 8.65 mOhm
Eaton HCF1007-4R7-R 4.7 uH High-Current Inductor 8.65 mOhm

Eaton HCF1007-4R7-R 4.7 uH High-Current Inductor 8.65 mOhm

Share
Eaton HCF1007-4R7-R: ferrite high-current power inductor, 4.7 uH ±20%, 9.4 A Irms, Isat 12 A, DCR 8.65 mOhm, 10.3 x 8.1 mm.
    • Product Details
    • Download

    Eaton HCF1007-4R7-R 4.7 uH High-Current Inductor 8.65 mOhm

    HCF1007-4R7-R at a glance: ferrite high-current power inductor, 4.7 uH ±20%, 9.4 A Irms, Isat 12 A (20% rolloff @ +25 °C), DCR 8.65 mOhm, 10.3 x 8.1 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHCF1007-4R7-R
    OCL (open circuit inductance)4.7 uH ±20%
    FLL minimum, at Isat3.38 uH
    Irms (DC, 40 °C rise)9.4 A
    Isat (20% rolloff @ +25 °C)12 A
    Isat2 (20% rolloff @ +125 °C)8.9 A
    DCR typical @ +20 °C8.65 mOhm
    K-factor (Bp-p = K x L x dI)70, Bp-p in Gauss
    Package10.3 x 8.1 mm
    Height6.65 mm
    MountingSurface mount
    Operating temperature-40 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4361

    Dimensions and Pad Layout

    HCF1007-4R7-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4361: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    Reading the Data Sheet

    This inductor uses a ferrite core with a winding arranged to present a high DC bias resistance. In practice that means the inductance holds up further into the load range than a plain ferrite part of the same size, and the part runs on converters that need low core loss rather than the soft saturation of a powder core.

    At the rated 9.4 A the winding dissipates about 0.764 W in copper alone, using the typical DCR of 8.65 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.

    The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    At Isat the part holds about 338 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    With K = 70, a peak-to-peak ripple of one amp produces roughly 329 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    The second saturation column, 8.9 A at 20% rolloff @ +125 °C, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.

    What This Family Is For

    The HCF family is the ferrite option in the high-current range: lower core loss than a powder part at high frequency, with saturation current quoted at both +25 °C and +125 °C. It is the family for converters that run fast and hot.

    Of the 12 values listed for HCF1007, this is the 9th, in a family covering 0.3 uH to 10 uH.

    Compared with its neighbours in the table, HCF1007-5R6-R trades 0.6 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: ferrite core, 10.3 x 8.1 mm body at 6.65 mm.
    • Typical applications: voltage regulator modules (vrm); high current dc-dc converters; multi-phase buck regulators; servers and data networking; point-of-load modules.
    • Ferrite loses saturation margin as it heats. The +125 °C Isat column is the one that governs a hot design; the +25 °C figure is the optimistic one.

    Design Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 8.65 mOhm becomes roughly 12.2 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the full-load inductance (FLL) is the value to use for ripple at rated current. OCL is the small-signal number; FLL is what the converter actually sees under load.

    • Check the full-load inductance against the ripple target at maximum load.
    • Read the core-loss curve at the Bp-p implied by the K-factor and the ripple.
    • Confirm the terminal arrangement matches the pad layout for three-terminal parts.

    Frequently Asked Questions

    What happens above the self-resonant frequency?
    The part becomes capacitive and no longer behaves as an inductor. Keep the switching frequency and the harmonics that carry energy comfortably below SRF where one is quoted.

    Why are there two saturation currents?
    Ferrite loses saturation flux density as it heats. The +25 °C column describes a bench measurement; the +125 °C column describes the part under load in a hot enclosure, which is the one that governs the design.

    Is this part suitable for current sensing?
    The family includes parts with tight DCR tolerance for exactly that purpose, but the tolerance is quoted at +20 °C. Copper drift with temperature has to be compensated in the sensing circuit.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products