| Parameter | Value |
|---|---|
| Orderable part number | HCF1007-5R6-R |
| OCL (open circuit inductance) | 5.6 uH ±20% |
| FLL minimum, at Isat | 4.03 uH |
| Irms (DC, 40 °C rise) | 9.4 A |
| Isat (20% rolloff @ +25 °C) | 9.4 A |
| Isat2 (20% rolloff @ +125 °C) | 7.5 A |
| DCR typical @ +20 °C | 8.65 mOhm |
| K-factor (Bp-p = K x L x dI) | 70, Bp-p in Gauss |
| Package | 10.3 x 8.1 mm |
| Height | 6.65 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4361 |

Drawing reproduced from Eaton Technical Data 4361: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Ferrite, tight DCR, high current: the family is aimed at switching converters where the inductor value has to be known accurately and the loss budget is tight. The data sheet quotes OCL, full-load inductance and saturation current separately so the three can be traded against each other.
With 8.65 mOhm typical, the I-squared-R loss at the full 9.4 A rating is about 0.764 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.
The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.
Stored energy at Isat is about 247 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.
K-factor 70 means the flux swing is about 392 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.
The second saturation column, 7.5 A at 20% rolloff @ +125 °C, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.
The HCF family is the ferrite option in the high-current range: lower core loss than a powder part at high frequency, with saturation current quoted at both +25 °C and +125 °C. It is the family for converters that run fast and hot.
Within the HCF1007 family this is value 10 of 12, in a range that runs from 0.3 uH to 10 uH.
One step down the table, HCF1007-4R7-R, sits at 4.7 uH with 9.4 A and 8.65 mOhm – the lower inductance buys about 0 A of extra current in the same body.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 8.65 mOhm becomes roughly 12.2 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the full-load inductance (FLL) is the value to use for ripple at rated current. OCL is the small-signal number; FLL is what the converter actually sees under load.
Is a three-terminal part a drop-in for a two-terminal one?
No. The third terminal is part of the construction and changes the pad layout and the current path, so the board needs the matching footprint.
Is a three-terminal part a drop-in for a two-terminal one?
No. The third terminal is part of the construction and changes the pad layout and the current path, so the board needs the matching footprint.
What happens above the self-resonant frequency?
The part becomes capacitive and no longer behaves as an inductor. Keep the switching frequency and the harmonics that carry energy comfortably below SRF where one is quoted.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd