Eaton HCF1007-6R8-R: ferrite high-current power inductor, 6.8 uH ±20%, 9.4 A Irms, Isat 7.8 A, DCR 8.65 mOhm, 10.3 x 8.1 mm.
    • Product Details
    • Download

    Eaton HCF1007-6R8-R 6.8 uH Low-Loss Power Inductor

    HCF1007-6R8-R at a glance: ferrite high-current power inductor, 6.8 uH ±20%, 9.4 A Irms, Isat 7.8 A (20% rolloff @ +25 °C), DCR 8.65 mOhm, 10.3 x 8.1 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHCF1007-6R8-R
    OCL (open circuit inductance)6.8 uH ±20%
    FLL minimum, at Isat4.9 uH
    Irms (DC, 40 °C rise)9.4 A
    Isat (20% rolloff @ +25 °C)7.8 A
    Isat2 (20% rolloff @ +125 °C)6.1 A
    DCR typical @ +20 °C8.65 mOhm
    K-factor (Bp-p = K x L x dI)70, Bp-p in Gauss
    Package10.3 x 8.1 mm
    Height6.65 mm
    MountingSurface mount
    Operating temperature-40 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4361

    Mechanical Dimensions & Pad Layout

    HCF1007-6R8-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4361: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    This inductor uses a ferrite core with a winding arranged to present a high DC bias resistance. In practice that means the inductance holds up further into the load range than a plain ferrite part of the same size, and the part runs on converters that need low core loss rather than the soft saturation of a powder core.

    Copper loss at the rated current works out to roughly 0.764 W from a typical DCR of 8.65 mOhm at 9.4 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    The core stores roughly 207 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.

    With K = 70, a peak-to-peak ripple of one amp produces roughly 476 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    The second saturation column, 6.1 A at 20% rolloff @ +125 °C, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.

    What This Family Is For

    The HCF family is the ferrite option in the high-current range: lower core loss than a powder part at high frequency, with saturation current quoted at both +25 °C and +125 °C. It is the family for converters that run fast and hot.

    The HCF1007 family spans 0.3 uH to 10 uH; this row sits at position 11 of 12.

    The next value up in the same family, HCF1007-100-R, gives 10.0 uH at 9.4 A and DCR 8.65 mOhm: the extra inductance costs about 0 A of rated current.

    • Core material: ferrite core, 10.3 x 8.1 mm body at 6.65 mm.
    • Typical applications: voltage regulator modules (vrm); high current dc-dc converters; multi-phase buck regulators; servers and data networking; point-of-load modules.
    • Ferrite loses saturation margin as it heats. The +125 °C Isat column is the one that governs a hot design; the +25 °C figure is the optimistic one.

    Putting It to Work

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 8.65 mOhm becomes roughly 12.2 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the full-load inductance (FLL) is the value to use for ripple at rated current. OCL is the small-signal number; FLL is what the converter actually sees under load.

    • Use the +125 °C saturation column for the current limit in the controller.
    • Calculate ripple with FLL, not OCL: the loaded inductance is what the converter sees.
    • Use the +125 °C saturation column for the current limit in the controller.

    Frequently Asked Questions

    Why are there two saturation currents?
    Ferrite loses saturation flux density as it heats. The +25 °C column describes a bench measurement; the +125 °C column describes the part under load in a hot enclosure, which is the one that governs the design.

    Why are there two saturation currents?
    Ferrite loses saturation flux density as it heats. The +25 °C column describes a bench measurement; the +125 °C column describes the part under load in a hot enclosure, which is the one that governs the design.

    How is the K-factor used?
    Multiply K by the inductance in microhenry and by the peak-to-peak ripple in amps to get the flux swing the core sees. Read the core-loss curve at that amplitude and at your switching frequency.