Eaton HCF1007-R30-R 0.30 uH High-Current Inductor 0.9 mOhm
Eaton HCF1007-R30-R 0.30 uH High-Current Inductor 0.9 mOhm

Eaton HCF1007-R30-R 0.30 uH High-Current Inductor 0.9 mOhm

Share
Eaton HCF1007-R30-R: ferrite high-current power inductor, 0.30 uH ±20%, 30 A Irms, Isat 48 A, DCR 0.9 mOhm, 10.3 x 8.1 mm.
    • Product Details
    • Download

    Eaton HCF1007-R30-R 0.30 uH High-Current Inductor 0.9 mOhm

    HCF1007-R30-R at a glance: ferrite high-current power inductor, 0.30 uH ±20%, 30 A Irms, Isat 48 A (20% rolloff @ +25 °C), DCR 0.9 mOhm, 10.3 x 8.1 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHCF1007-R30-R
    OCL (open circuit inductance)0.30 uH ±20%
    FLL minimum, at Isat0.21 uH
    Irms (DC, 40 °C rise)30 A
    Isat (20% rolloff @ +25 °C)48 A
    Isat2 (20% rolloff @ +125 °C)35 A
    DCR typical @ +20 °C0.9 mOhm
    K-factor (Bp-p = K x L x dI)280, Bp-p in Gauss
    Package10.3 x 8.1 mm
    Height6.65 mm
    MountingSurface mount
    Operating temperature-40 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4361

    Dimensions and Pad Layout

    HCF1007-R30-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4361: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    This inductor uses a ferrite core with a winding arranged to present a high DC bias resistance. In practice that means the inductance holds up further into the load range than a plain ferrite part of the same size, and the part runs on converters that need low core loss rather than the soft saturation of a powder core.

    With 0.9 mOhm typical, the I-squared-R loss at the full 30 A rating is about 0.81 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.

    Energy storage at the saturation current is around 346 uJ, the number that connects the inductance and the current rating into a single transient figure.

    With K = 280, a peak-to-peak ripple of one amp produces roughly 84 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    The second saturation column, 35 A at 20% rolloff @ +125 °C, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.

    Series Positioning

    The HCF family is the ferrite option in the high-current range: lower core loss than a powder part at high frequency, with saturation current quoted at both +25 °C and +125 °C. It is the family for converters that run fast and hot.

    In the HCF1007 line-up this part is number 1 of 12 by inductance, between 0.3 uH and 10 uH.

    The next value up in the same family, HCF1007-R42-R, gives 0.42 uH at 26 A and DCR 1.3 mOhm: the extra inductance costs about 0 A of rated current.

    • Core material: ferrite core, 10.3 x 8.1 mm body at 6.65 mm.
    • Typical applications: voltage regulator modules (vrm); high current dc-dc converters; multi-phase buck regulators; servers and data networking; point-of-load modules.
    • Ferrite loses saturation margin as it heats. The +125 °C Isat column is the one that governs a hot design; the +25 °C figure is the optimistic one.

    Putting It to Work

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 0.9 mOhm becomes roughly 1.27 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the full-load inductance (FLL) is the value to use for ripple at rated current. OCL is the small-signal number; FLL is what the converter actually sees under load.

    • Check saturation at the +125 °C column when the enclosure runs hot.
    • Check saturation at the +125 °C column when the enclosure runs hot.
    • Use the +125 °C saturation column for the current limit in the controller.

    Frequently Asked Questions

    Why are there two saturation currents?
    Ferrite loses saturation flux density as it heats. The +25 °C column describes a bench measurement; the +125 °C column describes the part under load in a hot enclosure, which is the one that governs the design.

    Is this part suitable for current sensing?
    The family includes parts with tight DCR tolerance for exactly that purpose, but the tolerance is quoted at +20 °C. Copper drift with temperature has to be compensated in the sensing circuit.

    Is this part suitable for current sensing?
    The family includes parts with tight DCR tolerance for exactly that purpose, but the tolerance is quoted at +20 °C. Copper drift with temperature has to be compensated in the sensing circuit.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products