| Parameter | Value |
|---|---|
| Orderable part number | HCF1007-R42-R |
| OCL (open circuit inductance) | 0.42 uH ±20% |
| FLL minimum, at Isat | 0.3 uH |
| Irms (DC, 40 °C rise) | 26 A |
| Isat (20% rolloff @ +25 °C) | 45 A |
| Isat2 (20% rolloff @ +125 °C) | 36 A |
| DCR typical @ +20 °C | 1.3 mOhm |
| K-factor (Bp-p = K x L x dI) | 187, Bp-p in Gauss |
| Package | 10.3 x 8.1 mm |
| Height | 6.65 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4361 |

Drawing reproduced from Eaton Technical Data 4361: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Ferrite core, high current, and a winding built to keep the DC resistance low: this family sits between the foil-wound parts and the molded powder parts. Ferrite gives low core loss at the switching frequency; the construction gives a low DCR and a tight tolerance, which matters when the inductor is also the current-sense element.
The DCR figure of 1.3 mOhm is what sets the efficiency: at 26 A the winding drops about 0.034 mV and dissipates 0.879 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.
The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.
At Isat the part holds about 425 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.
With K = 187, a peak-to-peak ripple of one amp produces roughly 78.4 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.
The second saturation column, 36 A at 20% rolloff @ +125 °C, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.
The HCF family is the ferrite option in the high-current range: lower core loss than a powder part at high frequency, with saturation current quoted at both +25 °C and +125 °C. It is the family for converters that run fast and hot.
Within the HCF1007 family this is value 2 of 12, in a range that runs from 0.3 uH to 10 uH.
One step down the table, HCF1007-R30-R, sits at 0.30 uH with 30 A and 0.9 mOhm – the lower inductance buys about 4 A of extra current in the same body.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 1.3 mOhm becomes roughly 1.84 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the full-load inductance (FLL) is the value to use for ripple at rated current. OCL is the small-signal number; FLL is what the converter actually sees under load.
Why are there two saturation currents?
Ferrite loses saturation flux density as it heats. The +25 °C column describes a bench measurement; the +125 °C column describes the part under load in a hot enclosure, which is the one that governs the design.
Is this part suitable for current sensing?
The family includes parts with tight DCR tolerance for exactly that purpose, but the tolerance is quoted at +20 °C. Copper drift with temperature has to be compensated in the sensing circuit.
Is this part suitable for current sensing?
The family includes parts with tight DCR tolerance for exactly that purpose, but the tolerance is quoted at +20 °C. Copper drift with temperature has to be compensated in the sensing circuit.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd