Eaton HCF1305-3R3-R 3.30 uH Ferrite Power Inductor, 13.2 A
Eaton HCF1305-3R3-R 3.30 uH Ferrite Power Inductor, 13.2 A

Eaton HCF1305-3R3-R 3.30 uH Ferrite Power Inductor, 13.2 A

Share
Eaton HCF1305-3R3-R: ferrite high-current power inductor, 3.30 uH ±20%, 13.2 A Irms, Isat 12.5 A, DCR 4.08 mOhm, 12.5 x 12.5 mm.
    • Product Details
    • Download

    Eaton HCF1305-3R3-R 3.30 uH Ferrite Power Inductor, 13.2 A

    HCF1305-3R3-R at a glance: ferrite high-current power inductor, 3.30 uH ±20%, 13.2 A Irms, Isat 12.5 A (30% rolloff @ +25 °C), DCR 4.08 mOhm, 12.5 x 12.5 mm.

    Specification Table

    ParameterValue
    Orderable part numberHCF1305-3R3-R
    Rated inductance3.3 uH ±20%
    OCL (open circuit inductance)3.30 uH ±20%
    Irms (DC, 40 °C rise)13.2 A
    Isat (30% rolloff @ +25 °C)12.5 A
    Isat2 (30% rolloff @ +125 °C)9 A
    DCR typical @ +20 °C4.08 mOhm
    DCR maximum @ +20 °C4.9 mOhm
    K-factor (Bp-p = K x L x dI)8.3, Bp-p in mT
    Package12.5 x 12.5 mm
    Height5.0 mm
    MountingSurface mount
    Operating temperature-40 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4133

    Outline Drawing

    HCF1305-3R3-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4133: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    Ferrite core, high current, and a winding built to keep the DC resistance low: this family sits between the foil-wound parts and the molded powder parts. Ferrite gives low core loss at the switching frequency; the construction gives a low DCR and a tight tolerance, which matters when the inductor is also the current-sense element.

    The DCR figure of 4.08 mOhm is what sets the efficiency: at 13.2 A the winding drops about 0.054 mV and dissipates 0.711 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.

    The Isat column is 30% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    Energy storage at the saturation current is around 258 uJ, the number that connects the inductance and the current rating into a single transient figure.

    With K = 8.3, a peak-to-peak ripple of one amp produces roughly 27.4 mT of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    The second saturation column, 9 A at 30% rolloff @ +125 °C, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.

    Positioning in the Range

    The HCF family is the ferrite option in the high-current range: lower core loss than a powder part at high frequency, with saturation current quoted at both +25 °C and +125 °C. It is the family for converters that run fast and hot.

    Of the 10 values listed for HCF1305, this is the 8th, in a family covering 0.47 uH to 4.7 uH.

    One step down the table, HCF1305-3R0-R, sits at 3.00 uH with 13.2 A and 4.08 mOhm – the lower inductance buys about 2.3 A of extra current in the same body.

    • Core material: ferrite core, 12.5 x 12.5 mm body at 5.0 mm.
    • Typical applications: voltage regulator modules (vrm); high current dc-dc converters; multi-phase buck regulators; servers and data networking; point-of-load modules.
    • Ferrite loses saturation margin as it heats. The +125 °C Isat column is the one that governs a hot design; the +25 °C figure is the optimistic one.

    Putting It to Work

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 4.9 mOhm becomes roughly 6.92 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the full-load inductance (FLL) is the value to use for ripple at rated current. OCL is the small-signal number; FLL is what the converter actually sees under load.

    • Calculate ripple with FLL, not OCL: the loaded inductance is what the converter sees.
    • Check the full-load inductance against the ripple target at maximum load.
    • Check the full-load inductance against the ripple target at maximum load.

    Frequently Asked Questions

    Is this part suitable for current sensing?
    The family includes parts with tight DCR tolerance for exactly that purpose, but the tolerance is quoted at +20 °C. Copper drift with temperature has to be compensated in the sensing circuit.

    Is a three-terminal part a drop-in for a two-terminal one?
    No. The third terminal is part of the construction and changes the pad layout and the current path, so the board needs the matching footprint.

    Is this part suitable for current sensing?
    The family includes parts with tight DCR tolerance for exactly that purpose, but the tolerance is quoted at +20 °C. Copper drift with temperature has to be compensated in the sensing circuit.

    Shenzhen Gaorunxin Technology Co., Ltd