Eaton HCF1305-R47-R 0.47 uH Low-Loss Power Inductor
Eaton HCF1305-R47-R 0.47 uH Low-Loss Power Inductor

Eaton HCF1305-R47-R 0.47 uH Low-Loss Power Inductor

Share
Eaton HCF1305-R47-R: ferrite high-current power inductor, 0.47 uH ±20%, 32 A Irms, Isat 36 A, DCR 0.83 mOhm, 12.5 x 12.5 mm.
    • Product Details
    • Download

    Eaton HCF1305-R47-R 0.47 uH Low-Loss Power Inductor

    HCF1305-R47-R at a glance: ferrite high-current power inductor, 0.47 uH ±20%, 32 A Irms, Isat 36 A (30% rolloff @ +25 °C), DCR 0.83 mOhm, 12.5 x 12.5 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHCF1305-R47-R
    Rated inductance0.47 uH ±20%
    OCL (open circuit inductance)0.47 uH ±20%
    Irms (DC, 40 °C rise)32 A
    Isat (30% rolloff @ +25 °C)36 A
    Isat2 (30% rolloff @ +125 °C)30 A
    DCR typical @ +20 °C0.83 mOhm
    DCR maximum @ +20 °C1 mOhm
    K-factor (Bp-p = K x L x dI)21, Bp-p in mT
    Package12.5 x 12.5 mm
    Height5.0 mm
    MountingSurface mount
    Operating temperature-40 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4133

    Outline Drawing

    HCF1305-R47-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4133: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    Reading the Data Sheet

    Ferrite, tight DCR, high current: the family is aimed at switching converters where the inductor value has to be known accurately and the loss budget is tight. The data sheet quotes OCL, full-load inductance and saturation current separately so the three can be traded against each other.

    At the rated 32 A the winding dissipates about 0.85 W in copper alone, using the typical DCR of 0.83 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.

    Isat is specified as 30% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.

    At Isat the part holds about 305 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    The K-factor of 21 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 9.9 mT of Bp-p, the figure the core-loss curve is plotted against.

    The second saturation column, 30 A at 30% rolloff @ +125 °C, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.

    Where This Series Fits

    The HCF family is the ferrite option in the high-current range: lower core loss than a powder part at high frequency, with saturation current quoted at both +25 °C and +125 °C. It is the family for converters that run fast and hot.

    Within the HCF1305 family this is value 1 of 10, in a range that runs from 0.47 uH to 4.7 uH.

    The next value up in the same family, HCF1305-R56-R, gives 0.56 uH at 32 A and DCR 0.83 mOhm: the extra inductance costs about 0 A of rated current.

    • Core material: ferrite core, 12.5 x 12.5 mm body at 5.0 mm.
    • Typical applications: voltage regulator modules (vrm); high current dc-dc converters; multi-phase buck regulators; servers and data networking; point-of-load modules.
    • Ferrite loses saturation margin as it heats. The +125 °C Isat column is the one that governs a hot design; the +25 °C figure is the optimistic one.

    Design Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 1 mOhm becomes roughly 1.41 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the full-load inductance (FLL) is the value to use for ripple at rated current. OCL is the small-signal number; FLL is what the converter actually sees under load.

    • Use the +125 °C saturation column for the current limit in the controller.
    • Check saturation at the +125 °C column when the enclosure runs hot.
    • Use the +125 °C saturation column for the current limit in the controller.

    Frequently Asked Questions

    How is the K-factor used?
    Multiply K by the inductance in microhenry and by the peak-to-peak ripple in amps to get the flux swing the core sees. Read the core-loss curve at that amplitude and at your switching frequency.

    How is the K-factor used?
    Multiply K by the inductance in microhenry and by the peak-to-peak ripple in amps to get the flux swing the core sees. Read the core-loss curve at that amplitude and at your switching frequency.

    What is the difference between OCL and FLL?
    OCL is the open-circuit inductance measured at low signal. FLL is the inductance remaining at the saturation current. Ripple at full load should be calculated with FLL, not OCL.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products