| Parameter | Value |
|---|---|
| Orderable part number | HCM0503-150-R |
| OCL (open circuit inductance) | 15 uH ±20% |
| FLL minimum, at Isat | 9.6 uH |
| Irms (DC, 40 °C rise) | 2.4 A |
| Isat (20% rolloff @ +25 °C) | 2.1 A |
| DCR typical @ +20 °C | 138 mOhm |
| DCR maximum @ +20 °C | 166 mOhm |
| K-factor (Bp-p = K x L x dI) | 127, Bp-p in Gauss |
| Package | 5.5 x 5.3 mm |
| Height | 3.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4430 |

Drawing reproduced from Eaton Technical Data 4430: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Molded construction is what gives this family its mechanical robustness and its shielding. Because the core surrounds the winding on all sides, the leakage field that would otherwise couple into adjacent traces is small, and the part can be placed close to sensitive nodes.
At the rated 2.4 A the winding dissipates about 0.797 W in copper alone, using the typical DCR of 138 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.
Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.
Energy storage at the saturation current is around 33.1 uJ, the number that connects the inductance and the current rating into a single transient figure.
K-factor 127 means the flux swing is about 1,905 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.
The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.
In the HCM0503 line-up this part is number 12 of 13 by inductance, between 0.2 uH and 22 uH.
The next value up in the same family, HCM0503-220-R, gives 22 uH at 1.9 A and DCR 260 mOhm: the extra inductance costs about 0.9 A of rated current.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 166 mOhm becomes roughly 235 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.
Can two parts be stacked for higher current?
Stacking halves the inductance and doubles the current capability in theory, but the two DCRs are not matched and the magnetic coupling is uncontrolled. Use a larger part instead.
Why quote typical and maximum DCR?
A guaranteed thermal design uses the maximum. A nominal efficiency calculation uses the typical. Publishing both lets the same table serve either purpose.
Can two parts be stacked for higher current?
Stacking halves the inductance and doubles the current capability in theory, but the two DCRs are not matched and the magnetic coupling is uncontrolled. Use a larger part instead.