Eaton HCM0503-1R0-R 1.0 uH Molded Power Inductor, 10.1 A
Eaton HCM0503-1R0-R 1.0 uH Molded Power Inductor, 10.1 A

Eaton HCM0503-1R0-R 1.0 uH Molded Power Inductor, 10.1 A

Share
Eaton HCM0503-1R0-R: molded high-current power inductor, 1.0 uH ±20%, 10.1 A Irms, Isat 8.5 A, DCR 10.4 mOhm, 5.5 x 5.3 mm.
    • Product Details
    • Download

    Eaton HCM0503-1R0-R 1.0 uH Molded Power Inductor, 10.1 A

    HCM0503-1R0-R at a glance: molded high-current power inductor, 1.0 uH ±20%, 10.1 A Irms, Isat 8.5 A (20% rolloff @ +25 °C), DCR 10.4 mOhm, 5.5 x 5.3 mm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberHCM0503-1R0-R
    OCL (open circuit inductance)1.0 uH ±20%
    FLL minimum, at Isat0.64 uH
    Irms (DC, 40 °C rise)10.1 A
    Isat (20% rolloff @ +25 °C)8.5 A
    DCR typical @ +20 °C10.4 mOhm
    DCR maximum @ +20 °C11.4 mOhm
    K-factor (Bp-p = K x L x dI)588, Bp-p in Gauss
    Package5.5 x 5.3 mm
    Height3.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4430

    Mechanical Drawing

    HCM0503-1R0-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4430: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    A molded body around an alloy or iron powder core: the winding is pressed into the magnetic material, so the field is contained inside the part and the terminals come straight out of the molding. The result is a shielded inductor with a low profile and a soft saturation curve, on a footprint that is almost all magnetic material.

    Copper loss at the rated current works out to roughly 1.06 W from a typical DCR of 10.4 mOhm at 10.1 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    The core stores roughly 36.1 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.

    With K = 588, a peak-to-peak ripple of one amp produces roughly 588 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    What This Family Is For

    The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.

    The HCM0503 family spans 0.2 uH to 22 uH; this row sits at position 5 of 13.

    Compared with its neighbours in the table, HCM0503-1R5-R trades 3.8 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: iron powder core, 5.5 x 5.3 mm body at 3.0 mm.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; point-of-load modules; desktop and server vrms and evrds; base station equipment; notebook and laptop regulators.
    • The DCR columns are typical and maximum at +20 °C. Copper rises about 0.4 % per °C, so the hot resistance is higher than either column suggests.

    Putting It to Work

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 11.4 mOhm becomes roughly 16.2 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.

    • Confirm the peak transient current stays under Isat with tolerance margin.
    • Allow for copper drift: resistance rises with temperature at roughly 0.4 % per °C.
    • Verify the body height against the enclosure or heat-spreader clearance.

    Frequently Asked Questions

    How much inductance is left at rated current?
    That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.

    What makes a molded inductor different?
    The winding is pressed into the magnetic powder with no bobbin or air gap in the path. That is why the body is almost all magnetic material, the DCR is low for the size, and the part is mechanically robust.

    Why quote typical and maximum DCR?
    A guaranteed thermal design uses the maximum. A nominal efficiency calculation uses the typical. Publishing both lets the same table serve either purpose.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products