Eaton HCM0503-4R7-R 4.7 uH Molded Power Inductor, 4.5 A
Eaton HCM0503-4R7-R 4.7 uH Molded Power Inductor, 4.5 A

Eaton HCM0503-4R7-R 4.7 uH Molded Power Inductor, 4.5 A

Share
Eaton HCM0503-4R7-R: molded high-current power inductor, 4.7 uH ±20%, 4.5 A Irms, Isat 5.5 A, DCR 54 mOhm, 5.5 x 5.3 mm.
    • Product Details
    • Download

    Eaton HCM0503-4R7-R 4.7 uH Molded Power Inductor, 4.5 A

    HCM0503-4R7-R at a glance: molded high-current power inductor, 4.7 uH ±20%, 4.5 A Irms, Isat 5.5 A (20% rolloff @ +25 °C), DCR 54 mOhm, 5.5 x 5.3 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHCM0503-4R7-R
    OCL (open circuit inductance)4.7 uH ±20%
    FLL minimum, at Isat3 uH
    Irms (DC, 40 °C rise)4.5 A
    Isat (20% rolloff @ +25 °C)5.5 A
    DCR typical @ +20 °C54 mOhm
    DCR maximum @ +20 °C60 mOhm
    K-factor (Bp-p = K x L x dI)226, Bp-p in Gauss
    Package5.5 x 5.3 mm
    Height3.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4430

    Dimensions and Pad Layout

    HCM0503-4R7-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4430: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    The part is a surface-mount molded inductor: powder core, directly wound and pressed, with the terminals formed from the winding ends. The absence of a bobbin or an air gap in the magnetic path is what keeps the DCR low for the current rating, and the soft saturation is a property of the distributed gap.

    With 54 mOhm typical, the I-squared-R loss at the full 4.5 A rating is about 1.09 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.

    Energy storage at the saturation current is around 71.1 uJ, the number that connects the inductance and the current rating into a single transient figure.

    The K-factor of 226 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 1,062 Gauss of Bp-p, the figure the core-loss curve is plotted against.

    Series Positioning

    The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.

    Within the HCM0503 family this is value 9 of 13, in a range that runs from 0.2 uH to 22 uH.

    The next value up in the same family, HCM0503-5R6-R, gives 5.6 uH at 4.3 A and DCR 63 mOhm: the extra inductance costs about 1.2 A of rated current.

    • Core material: iron powder core, 5.5 x 5.3 mm body at 3.0 mm.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; point-of-load modules; desktop and server vrms and evrds; base station equipment; notebook and laptop regulators.
    • The DCR columns are typical and maximum at +20 °C. Copper rises about 0.4 % per °C, so the hot resistance is higher than either column suggests.

    Putting It to Work

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 60 mOhm becomes roughly 84.8 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.

    • Confirm the shielding is adequate for the adjacent trace routing.
    • Build the thermal design on the maximum DCR, not the typical one.
    • Build the thermal design on the maximum DCR, not the typical one.

    Frequently Asked Questions

    How much does the inductance drop at rated current?
    That is what the Isat column quantifies. At the rated DC current the part is still inside the rolloff boundary, but the ripple calculation should use the FLL column rather than OCL.

    Is it magnetically shielded?
    Yes. The powder core surrounds the winding, so the leakage field is small and the part can sit close to sensitive traces without a shield can.

    Is it magnetically shielded?
    Yes. The powder core surrounds the winding, so the leakage field is small and the part can sit close to sensitive traces without a shield can.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products