Eaton HCM0503-R47-R Molded Inductor 0.47 uH, Isat 11.5 A
Eaton HCM0503-R47-R Molded Inductor 0.47 uH, Isat 11.5 A

Eaton HCM0503-R47-R Molded Inductor 0.47 uH, Isat 11.5 A

Share
Eaton HCM0503-R47-R: molded high-current power inductor, 0.47 uH ±20%, 12 A Irms, Isat 11.5 A, DCR 6.5 mOhm, 5.5 x 5.3 mm.
    • Product Details
    • Download

    Eaton HCM0503-R47-R Molded Inductor 0.47 uH, Isat 11.5 A

    HCM0503-R47-R at a glance: molded high-current power inductor, 0.47 uH ±20%, 12 A Irms, Isat 11.5 A (20% rolloff @ +25 °C), DCR 6.5 mOhm, 5.5 x 5.3 mm.

    Specification Table

    ParameterValue
    Orderable part numberHCM0503-R47-R
    OCL (open circuit inductance)0.47 uH ±20%
    FLL minimum, at Isat0.3 uH
    Irms (DC, 40 °C rise)12 A
    Isat (20% rolloff @ +25 °C)11.5 A
    DCR typical @ +20 °C6.5 mOhm
    DCR maximum @ +20 °C7.15 mOhm
    K-factor (Bp-p = K x L x dI)820, Bp-p in Gauss
    Package5.5 x 5.3 mm
    Height3.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4430

    Mechanical Dimensions & Pad Layout

    HCM0503-R47-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4430: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    Reading the Data Sheet

    The part is a surface-mount molded inductor: powder core, directly wound and pressed, with the terminals formed from the winding ends. The absence of a bobbin or an air gap in the magnetic path is what keeps the DCR low for the current rating, and the soft saturation is a property of the distributed gap.

    The DCR figure of 6.5 mOhm is what sets the efficiency: at 12 A the winding drops about 0.078 mV and dissipates 0.936 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.

    The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    The core stores roughly 31.1 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.

    K-factor 820 means the flux swing is about 385 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    Positioning in the Range

    The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.

    The HCM0503 family spans 0.2 uH to 22 uH; this row sits at position 3 of 13.

    The next value up in the same family, HCM0503-R75-R, gives 0.75 uH at 11.3 A and DCR 8.5 mOhm: the extra inductance costs about 5.3 A of rated current.

    • Core material: iron powder core, 5.5 x 5.3 mm body at 3.0 mm.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; point-of-load modules; desktop and server vrms and evrds; base station equipment; notebook and laptop regulators.
    • The DCR columns are typical and maximum at +20 °C. Copper rises about 0.4 % per °C, so the hot resistance is higher than either column suggests.

    Sizing and Layout Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 7.15 mOhm becomes roughly 10.1 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.

    • Confirm the shielding is adequate for the adjacent trace routing.
    • Build the thermal design on the maximum DCR, not the typical one.
    • Build the thermal design on the maximum DCR, not the typical one.

    Frequently Asked Questions

    How much inductance is left at rated current?
    That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.

    Is it magnetically shielded?
    Yes. The powder core surrounds the winding, so the leakage field is small and the part can sit close to sensitive traces without a shield can.

    How much does the inductance drop at rated current?
    That is what the Isat column quantifies. At the rated DC current the part is still inside the rolloff boundary, but the ripple calculation should use the FLL column rather than OCL.