Eaton HCM0703-R22-R: molded high-current power inductor, 0.22 uH ±20%, 23 A Irms, Isat 40 A, DCR 2.5 mOhm, 7.4 x 6.8 mm.
    • Product Details
    • Download

    Eaton HCM0703-R22-R Molded Inductor 0.22 uH, Isat 40 A

    HCM0703-R22-R at a glance: molded high-current power inductor, 0.22 uH ±20%, 23 A Irms, Isat 40 A (20% rolloff @ +25 °C), DCR 2.5 mOhm, 7.4 x 6.8 mm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberHCM0703-R22-R
    OCL (open circuit inductance)0.22 uH ±20%
    FLL minimum, at Isat0.13 uH
    Irms (DC, 40 °C rise)23 A
    Isat (20% rolloff @ +25 °C)40 A
    DCR typical @ +20 °C2.5 mOhm
    DCR maximum @ +20 °C2.8 mOhm
    K-factor (Bp-p = K x L x dI)986, Bp-p in Gauss
    Package7.4 x 6.8 mm
    Height3.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4085

    Mechanical Drawing

    HCM0703-R22-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4085: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    Reading the Data Sheet

    This is one of the molded power inductors used across VRM, point-of-load and multiphase regulator designs. The family covers a wide inductance range in standard footprints, and every row is characterised for both typical and maximum DCR so the loss budget can be built either way.

    At the rated 23 A the winding dissipates about 1.32 W in copper alone, using the typical DCR of 2.5 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.

    The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    Stored energy at Isat is about 176 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.

    With K = 986, a peak-to-peak ripple of one amp produces roughly 217 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    What This Family Is For

    The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.

    Within the HCM0703 family this is value 2 of 16, in a range that runs from 0.15 uH to 33 uH.

    The next value up in the same family, HCM0703-R47-R, gives 0.47 uH at 17.5 A and DCR 4 mOhm: the extra inductance costs about 8.5 A of rated current.

    • Core material: iron powder core, 7.4 x 6.8 mm body at 3.0 mm.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; point-of-loadmodules; desktop and server vrms and evrds; base station equipment; laptop and notebook regulators.
    • The DCR columns are typical and maximum at +20 °C. Copper rises about 0.4 % per °C, so the hot resistance is higher than either column suggests.

    Sizing It Into a Design

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 2.8 mOhm becomes roughly 3.96 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.

    • Confirm the shielding is adequate for the adjacent trace routing.
    • Allow for copper drift: resistance rises with temperature at roughly 0.4 % per °C.
    • Confirm the peak transient current stays under Isat with tolerance margin.

    Frequently Asked Questions

    Can two parts be stacked for higher current?
    Stacking halves the inductance and doubles the current capability in theory, but the two DCRs are not matched and the magnetic coupling is uncontrolled. Use a larger part instead.

    How much does the inductance drop at rated current?
    That is what the Isat column quantifies. At the rated DC current the part is still inside the rolloff boundary, but the ripple calculation should use the FLL column rather than OCL.

    Why quote typical and maximum DCR?
    A guaranteed thermal design uses the maximum. A nominal efficiency calculation uses the typical. Publishing both lets the same table serve either purpose.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products