| Parameter | Value |
|---|---|
| Orderable part number | HCM1103-100-R |
| OCL (open circuit inductance) | 10.0 uH ±20% |
| FLL minimum, at Isat | 5.6 uH |
| Irms (DC, 40 °C rise) | 5 A |
| Isat (20% rolloff @ +25 °C) | 7.5 A |
| DCR typical @ +20 °C | 40 mOhm |
| DCR maximum @ +20 °C | 44 mOhm |
| K-factor (Bp-p = K x L x dI) | 141, Bp-p in Gauss |
| Package | 11.5 x 10.3 mm |
| Height | 3.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4449 |

Drawing reproduced from Eaton Technical Data 4449: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Molded construction is what gives this family its mechanical robustness and its shielding. Because the core surrounds the winding on all sides, the leakage field that would otherwise couple into adjacent traces is small, and the part can be placed close to sensitive nodes.
The DCR figure of 40 mOhm is what sets the efficiency: at 5 A the winding drops about 0.2 mV and dissipates 1 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.
The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.
Stored energy at Isat is about 281 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.
The K-factor of 141 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 1,410 Gauss of Bp-p, the figure the core-loss curve is plotted against.
The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.
Of the 12 values listed for HCM1103, this is the 10th, in a family covering 0.12 uH to 22 uH.
The next value up in the same family, HCM1103-150-R, gives 15.0 uH at 4 A and DCR 59 mOhm: the extra inductance costs about 1 A of rated current.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 44 mOhm becomes roughly 62.2 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.
How much inductance is left at rated current?
That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.
How much inductance is left at rated current?
That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.
What makes a molded inductor different?
The winding is pressed into the magnetic powder with no bobbin or air gap in the path. That is why the body is almost all magnetic material, the DCR is low for the size, and the part is mechanically robust.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd