Eaton HCM1103-220-R 22.0 uH Molded Power Inductor, 3 A
Eaton HCM1103-220-R 22.0 uH Molded Power Inductor, 3 A

Eaton HCM1103-220-R 22.0 uH Molded Power Inductor, 3 A

Share
Eaton HCM1103-220-R: molded high-current power inductor, 22.0 uH ±20%, 3 A Irms, Isat 5 A, DCR 90 mOhm, 11.5 x 10.3 mm.
    • Product Details
    • Download

    Eaton HCM1103-220-R 22.0 uH Molded Power Inductor, 3 A

    HCM1103-220-R at a glance: molded high-current power inductor, 22.0 uH ±20%, 3 A Irms, Isat 5 A (20% rolloff @ +25 °C), DCR 90 mOhm, 11.5 x 10.3 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHCM1103-220-R
    OCL (open circuit inductance)22.0 uH ±20%
    FLL minimum, at Isat12.3 uH
    Irms (DC, 40 °C rise)3 A
    Isat (20% rolloff @ +25 °C)5 A
    DCR typical @ +20 °C90 mOhm
    DCR maximum @ +20 °C99 mOhm
    K-factor (Bp-p = K x L x dI)91, Bp-p in Gauss
    Package11.5 x 10.3 mm
    Height3.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4449

    Dimensions and Pad Layout

    HCM1103-220-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4449: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    This is one of the molded power inductors used across VRM, point-of-load and multiphase regulator designs. The family covers a wide inductance range in standard footprints, and every row is characterised for both typical and maximum DCR so the loss budget can be built either way.

    With 90 mOhm typical, the I-squared-R loss at the full 3 A rating is about 0.81 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    At Isat the part holds about 275 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    With K = 91, a peak-to-peak ripple of one amp produces roughly 2,002 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Positioning in the Range

    The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.

    Within the HCM1103 family this is value 12 of 12, in a range that runs from 0.12 uH to 22 uH.

    Compared with its neighbours in the table, HCM1103-150-R trades 0 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: iron powder core, 11.5 x 10.3 mm body at 3.0 mm.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; point-of-load modules; desktop and server vrms and evrds; base station equipment; notebook and laptop regulators.
    • The DCR columns are typical and maximum at +20 °C. Copper rises about 0.4 % per °C, so the hot resistance is higher than either column suggests.

    Sizing It Into a Design

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 99 mOhm becomes roughly 140 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.

    • Check the hot DCR before signing off the efficiency budget.
    • Check the hot DCR before signing off the efficiency budget.
    • Confirm the peak transient current stays under Isat with tolerance margin.

    Frequently Asked Questions

    Why quote typical and maximum DCR?
    A guaranteed thermal design uses the maximum. A nominal efficiency calculation uses the typical. Publishing both lets the same table serve either purpose.

    How much inductance is left at rated current?
    That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.

    How much inductance is left at rated current?
    That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products