| Parameter | Value |
|---|---|
| Orderable part number | HCM1103-R47-R |
| OCL (open circuit inductance) | 0.47 uH ±20% |
| FLL minimum, at Isat | 0.33 uH |
| Irms (DC, 40 °C rise) | 20 A |
| Isat (20% rolloff @ +25 °C) | 26 A |
| DCR typical @ +20 °C | 1.5 mOhm |
| DCR maximum @ +20 °C | 2 mOhm |
| K-factor (Bp-p = K x L x dI) | 515, Bp-p in Gauss |
| Package | 11.5 x 10.3 mm |
| Height | 3.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4449 |

Drawing reproduced from Eaton Technical Data 4449: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
The part is a surface-mount molded inductor: powder core, directly wound and pressed, with the terminals formed from the winding ends. The absence of a bobbin or an air gap in the magnetic path is what keeps the DCR low for the current rating, and the soft saturation is a property of the distributed gap.
The DCR figure of 1.5 mOhm is what sets the efficiency: at 20 A the winding drops about 0.03 mV and dissipates 0.6 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.
The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.
At Isat the part holds about 159 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.
With K = 515, a peak-to-peak ripple of one amp produces roughly 242 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.
The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.
Of the 12 values listed for HCM1103, this is the 3th, in a family covering 0.12 uH to 22 uH.
One step down the table, HCM1103-R36-R, sits at 0.36 uH with 23 A and 1.1 mOhm – the lower inductance buys about 2 A of extra current in the same body.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 2 mOhm becomes roughly 2.83 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.
Why quote typical and maximum DCR?
A guaranteed thermal design uses the maximum. A nominal efficiency calculation uses the typical. Publishing both lets the same table serve either purpose.
Is it magnetically shielded?
Yes. The powder core surrounds the winding, so the leakage field is small and the part can sit close to sensitive traces without a shield can.
How much inductance is left at rated current?
That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.