Eaton HCM1103-R68-R 0.68 uH Shielded Power Inductor
Eaton HCM1103-R68-R 0.68 uH Shielded Power Inductor

Eaton HCM1103-R68-R 0.68 uH Shielded Power Inductor

Share
Eaton HCM1103-R68-R: molded high-current power inductor, 0.68 uH ±20%, 21 A Irms, Isat 23 A, DCR 2.9 mOhm, 11.5 x 10.3 mm.
    • Product Details
    • Download

    Eaton HCM1103-R68-R 0.68 uH Shielded Power Inductor

    HCM1103-R68-R at a glance: molded high-current power inductor, 0.68 uH ±20%, 21 A Irms, Isat 23 A (20% rolloff @ +25 °C), DCR 2.9 mOhm, 11.5 x 10.3 mm.

    Specification Table

    ParameterValue
    Orderable part numberHCM1103-R68-R
    OCL (open circuit inductance)0.68 uH ±20%
    FLL minimum, at Isat0.38 uH
    Irms (DC, 40 °C rise)21 A
    Isat (20% rolloff @ +25 °C)23 A
    DCR typical @ +20 °C2.9 mOhm
    DCR maximum @ +20 °C3.4 mOhm
    K-factor (Bp-p = K x L x dI)510, Bp-p in Gauss
    Package11.5 x 10.3 mm
    Height3.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4449

    Dimensions and Pad Layout

    HCM1103-R68-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4449: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    A molded body around an alloy or iron powder core: the winding is pressed into the magnetic material, so the field is contained inside the part and the terminals come straight out of the molding. The result is a shielded inductor with a low profile and a soft saturation curve, on a footprint that is almost all magnetic material.

    The DCR figure of 2.9 mOhm is what sets the efficiency: at 21 A the winding drops about 0.061 mV and dissipates 1.28 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.

    The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    Energy storage at the saturation current is around 180 uJ, the number that connects the inductance and the current rating into a single transient figure.

    With K = 510, a peak-to-peak ripple of one amp produces roughly 347 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Positioning in the Range

    The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.

    Within the HCM1103 family this is value 4 of 12, in a range that runs from 0.12 uH to 22 uH.

    Compared with its neighbours in the table, HCM1103-1R0-R trades 5 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: iron powder core, 11.5 x 10.3 mm body at 3.0 mm.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; point-of-load modules; desktop and server vrms and evrds; base station equipment; notebook and laptop regulators.
    • The DCR columns are typical and maximum at +20 °C. Copper rises about 0.4 % per °C, so the hot resistance is higher than either column suggests.

    Putting It to Work

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 3.4 mOhm becomes roughly 4.8 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.

    • Allow for copper drift: resistance rises with temperature at roughly 0.4 % per °C.
    • Confirm the shielding is adequate for the adjacent trace routing.
    • Confirm the shielding is adequate for the adjacent trace routing.

    Frequently Asked Questions

    How much inductance is left at rated current?
    That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.

    Can two parts be stacked for higher current?
    Stacking halves the inductance and doubles the current capability in theory, but the two DCRs are not matched and the magnetic coupling is uncontrolled. Use a larger part instead.

    How much inductance is left at rated current?
    That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products