Eaton HCM1104-1R0-R 1.0 uH High-Current Inductor 3 mOhm
Eaton HCM1104-1R0-R 1.0 uH High-Current Inductor 3 mOhm

Eaton HCM1104-1R0-R 1.0 uH High-Current Inductor 3 mOhm

Share
Eaton HCM1104-1R0-R: molded high-current power inductor, 1.0 uH ±20%, 18 A Irms, Isat 28 A, DCR 3 mOhm, 11.5 x 10.3 mm.
    • Product Details
    • Download

    Eaton HCM1104-1R0-R 1.0 uH High-Current Inductor 3 mOhm

    HCM1104-1R0-R at a glance: molded high-current power inductor, 1.0 uH ±20%, 18 A Irms, Isat 28 A (20% rolloff @ +25 °C), DCR 3 mOhm, 11.5 x 10.3 mm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberHCM1104-1R0-R
    OCL (open circuit inductance)1.0 uH ±20%
    FLL minimum, at Isat0.56 uH
    Irms (DC, 40 °C rise)18 A
    Isat (20% rolloff @ +25 °C)28 A
    DCR typical @ +20 °C3 mOhm
    DCR maximum @ +20 °C3.3 mOhm
    K-factor (Bp-p = K x L x dI)378, Bp-p in Gauss
    Package11.5 x 10.3 mm
    Height4.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4370

    Mechanical Drawing

    HCM1104-1R0-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4370: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    A molded body around an alloy or iron powder core: the winding is pressed into the magnetic material, so the field is contained inside the part and the terminals come straight out of the molding. The result is a shielded inductor with a low profile and a soft saturation curve, on a footprint that is almost all magnetic material.

    Copper loss at the rated current works out to roughly 0.972 W from a typical DCR of 3 mOhm at 18 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.

    The core stores roughly 392 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.

    K-factor 378 means the flux swing is about 378 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    Where This Series Fits

    The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.

    In the HCM1104 line-up this part is number 6 of 12 by inductance, between 0.2 uH and 22 uH.

    The next value up in the same family, HCM1104-1R5-R, gives 1.5 uH at 16 A and DCR 3.8 mOhm: the extra inductance costs about 6 A of rated current.

    • Core material: iron powder core, 11.5 x 10.3 mm body at 4.0 mm.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; point-of-load modules; desktop and server vrms and evrds; base station equipment; notebook and laptop regulators.
    • The DCR columns are typical and maximum at +20 °C. Copper rises about 0.4 % per °C, so the hot resistance is higher than either column suggests.

    Sizing and Layout Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 3.3 mOhm becomes roughly 4.66 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.

    • Check the hot DCR before signing off the efficiency budget.
    • Verify the body height against the enclosure or heat-spreader clearance.
    • Check the hot DCR before signing off the efficiency budget.

    Frequently Asked Questions

    Is it magnetically shielded?
    Yes. The powder core surrounds the winding, so the leakage field is small and the part can sit close to sensitive traces without a shield can.

    How much does the inductance drop at rated current?
    That is what the Isat column quantifies. At the rated DC current the part is still inside the rolloff boundary, but the ripple calculation should use the FLL column rather than OCL.

    How much does the inductance drop at rated current?
    That is what the Isat column quantifies. At the rated DC current the part is still inside the rolloff boundary, but the ripple calculation should use the FLL column rather than OCL.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products