| Parameter | Value |
|---|---|
| Orderable part number | HCM1104-1R0-R |
| OCL (open circuit inductance) | 1.0 uH ±20% |
| FLL minimum, at Isat | 0.56 uH |
| Irms (DC, 40 °C rise) | 18 A |
| Isat (20% rolloff @ +25 °C) | 28 A |
| DCR typical @ +20 °C | 3 mOhm |
| DCR maximum @ +20 °C | 3.3 mOhm |
| K-factor (Bp-p = K x L x dI) | 378, Bp-p in Gauss |
| Package | 11.5 x 10.3 mm |
| Height | 4.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4370 |

Drawing reproduced from Eaton Technical Data 4370: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
A molded body around an alloy or iron powder core: the winding is pressed into the magnetic material, so the field is contained inside the part and the terminals come straight out of the molding. The result is a shielded inductor with a low profile and a soft saturation curve, on a footprint that is almost all magnetic material.
Copper loss at the rated current works out to roughly 0.972 W from a typical DCR of 3 mOhm at 18 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.
The core stores roughly 392 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.
K-factor 378 means the flux swing is about 378 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.
The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.
In the HCM1104 line-up this part is number 6 of 12 by inductance, between 0.2 uH and 22 uH.
The next value up in the same family, HCM1104-1R5-R, gives 1.5 uH at 16 A and DCR 3.8 mOhm: the extra inductance costs about 6 A of rated current.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 3.3 mOhm becomes roughly 4.66 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.
Is it magnetically shielded?
Yes. The powder core surrounds the winding, so the leakage field is small and the part can sit close to sensitive traces without a shield can.
How much does the inductance drop at rated current?
That is what the Isat column quantifies. At the rated DC current the part is still inside the rolloff boundary, but the ripple calculation should use the FLL column rather than OCL.
How much does the inductance drop at rated current?
That is what the Isat column quantifies. At the rated DC current the part is still inside the rolloff boundary, but the ripple calculation should use the FLL column rather than OCL.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd