Eaton HCM1104-1R5-R 1.5 uH Molded Power Inductor, 16 A
Eaton HCM1104-1R5-R 1.5 uH Molded Power Inductor, 16 A

Eaton HCM1104-1R5-R 1.5 uH Molded Power Inductor, 16 A

Share
Eaton HCM1104-1R5-R: molded high-current power inductor, 1.5 uH ±20%, 16 A Irms, Isat 32 A, DCR 3.8 mOhm, 11.5 x 10.3 mm.
    • Product Details
    • Download

    Eaton HCM1104-1R5-R 1.5 uH Molded Power Inductor, 16 A

    HCM1104-1R5-R at a glance: molded high-current power inductor, 1.5 uH ±20%, 16 A Irms, Isat 32 A (20% rolloff @ +25 °C), DCR 3.8 mOhm, 11.5 x 10.3 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHCM1104-1R5-R
    OCL (open circuit inductance)1.5 uH ±20%
    FLL minimum, at Isat0.84 uH
    Irms (DC, 40 °C rise)16 A
    Isat (20% rolloff @ +25 °C)32 A
    DCR typical @ +20 °C3.8 mOhm
    DCR maximum @ +20 °C4.2 mOhm
    K-factor (Bp-p = K x L x dI)310, Bp-p in Gauss
    Package11.5 x 10.3 mm
    Height4.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4370

    Dimensions and Pad Layout

    HCM1104-1R5-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4370: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    This is one of the molded power inductors used across VRM, point-of-load and multiphase regulator designs. The family covers a wide inductance range in standard footprints, and every row is characterised for both typical and maximum DCR so the loss budget can be built either way.

    With 3.8 mOhm typical, the I-squared-R loss at the full 16 A rating is about 0.973 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    Energy storage at the saturation current is around 768 uJ, the number that connects the inductance and the current rating into a single transient figure.

    With K = 310, a peak-to-peak ripple of one amp produces roughly 465 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Positioning in the Range

    The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.

    Within the HCM1104 family this is value 7 of 12, in a range that runs from 0.2 uH to 22 uH.

    One step down the table, HCM1104-1R0-R, sits at 1.0 uH with 18 A and 3 mOhm – the lower inductance buys about 6 A of extra current in the same body.

    • Core material: iron powder core, 11.5 x 10.3 mm body at 4.0 mm.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; point-of-load modules; desktop and server vrms and evrds; base station equipment; notebook and laptop regulators.
    • The DCR columns are typical and maximum at +20 °C. Copper rises about 0.4 % per °C, so the hot resistance is higher than either column suggests.

    Sizing and Layout Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 4.2 mOhm becomes roughly 5.93 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.

    • Allow for copper drift: resistance rises with temperature at roughly 0.4 % per °C.
    • Confirm the peak transient current stays under Isat with tolerance margin.
    • Confirm the peak transient current stays under Isat with tolerance margin.

    Frequently Asked Questions

    Why quote typical and maximum DCR?
    A guaranteed thermal design uses the maximum. A nominal efficiency calculation uses the typical. Publishing both lets the same table serve either purpose.

    How much inductance is left at rated current?
    That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.

    How much inductance is left at rated current?
    That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.