Eaton HCM1104-3R3-R Molded Inductor 3.3 uH, Isat 16 A
Eaton HCM1104-3R3-R Molded Inductor 3.3 uH, Isat 16 A

Eaton HCM1104-3R3-R Molded Inductor 3.3 uH, Isat 16 A

Share
Eaton HCM1104-3R3-R: molded high-current power inductor, 3.3 uH ±20%, 10 A Irms, Isat 16 A, DCR 10.8 mOhm, 11.5 x 10.3 mm.
    • Product Details
    • Download

    Eaton HCM1104-3R3-R Molded Inductor 3.3 uH, Isat 16 A

    HCM1104-3R3-R at a glance: molded high-current power inductor, 3.3 uH ±20%, 10 A Irms, Isat 16 A (20% rolloff @ +25 °C), DCR 10.8 mOhm, 11.5 x 10.3 mm.

    Specification Table

    ParameterValue
    Orderable part numberHCM1104-3R3-R
    OCL (open circuit inductance)3.3 uH ±20%
    FLL minimum, at Isat1.85 uH
    Irms (DC, 40 °C rise)10 A
    Isat (20% rolloff @ +25 °C)16 A
    DCR typical @ +20 °C10.8 mOhm
    DCR maximum @ +20 °C11.8 mOhm
    K-factor (Bp-p = K x L x dI)220, Bp-p in Gauss
    Package11.5 x 10.3 mm
    Height4.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4370

    Outline Drawing

    HCM1104-3R3-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4370: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    A molded body around an alloy or iron powder core: the winding is pressed into the magnetic material, so the field is contained inside the part and the terminals come straight out of the molding. The result is a shielded inductor with a low profile and a soft saturation curve, on a footprint that is almost all magnetic material.

    At the rated 10 A the winding dissipates about 1.08 W in copper alone, using the typical DCR of 10.8 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.

    Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.

    At Isat the part holds about 422 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    With K = 220, a peak-to-peak ripple of one amp produces roughly 726 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Where This Series Fits

    The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.

    The HCM1104 family spans 0.2 uH to 22 uH; this row sits at position 9 of 12.

    Compared with its neighbours in the table, HCM1104-4R7-R trades 3.5 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: iron powder core, 11.5 x 10.3 mm body at 4.0 mm.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; point-of-load modules; desktop and server vrms and evrds; base station equipment; notebook and laptop regulators.
    • The DCR columns are typical and maximum at +20 °C. Copper rises about 0.4 % per °C, so the hot resistance is higher than either column suggests.

    Design Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 11.8 mOhm becomes roughly 16.7 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.

    • Build the thermal design on the maximum DCR, not the typical one.
    • Verify the body height against the enclosure or heat-spreader clearance.
    • Confirm the shielding is adequate for the adjacent trace routing.

    Frequently Asked Questions

    Can two parts be stacked for higher current?
    Stacking halves the inductance and doubles the current capability in theory, but the two DCRs are not matched and the magnetic coupling is uncontrolled. Use a larger part instead.

    How much does the inductance drop at rated current?
    That is what the Isat column quantifies. At the rated DC current the part is still inside the rolloff boundary, but the ripple calculation should use the FLL column rather than OCL.

    How much inductance is left at rated current?
    That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products