| Parameter | Value |
|---|---|
| Orderable part number | HCM1104-R20-R |
| OCL (open circuit inductance) | 0.20 uH ±20% |
| FLL minimum, at Isat | 0.13 uH |
| Irms (DC, 40 °C rise) | 32 A |
| Isat (20% rolloff @ +25 °C) | 45 A |
| DCR typical @ +20 °C | 0.63 mOhm |
| DCR maximum @ +20 °C | 0.72 mOhm |
| K-factor (Bp-p = K x L x dI) | 411, Bp-p in Gauss |
| Package | 11.5 x 10.3 mm |
| Height | 4.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4370 |

Drawing reproduced from Eaton Technical Data 4370: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
This is one of the molded power inductors used across VRM, point-of-load and multiphase regulator designs. The family covers a wide inductance range in standard footprints, and every row is characterised for both typical and maximum DCR so the loss budget can be built either way.
Copper loss at the rated current works out to roughly 0.645 W from a typical DCR of 0.63 mOhm at 32 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.
Energy storage at the saturation current is around 202 uJ, the number that connects the inductance and the current rating into a single transient figure.
With K = 411, a peak-to-peak ripple of one amp produces roughly 82.2 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.
The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.
The HCM1104 family spans 0.2 uH to 22 uH; this row sits at position 1 of 12.
One step down the table, HCM1104-R36-R, sits at 0.36 uH with 30 A and 1.04 mOhm – the lower inductance buys about 0 A of extra current in the same body.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 0.72 mOhm becomes roughly 1.02 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.
Can two parts be stacked for higher current?
Stacking halves the inductance and doubles the current capability in theory, but the two DCRs are not matched and the magnetic coupling is uncontrolled. Use a larger part instead.
Why quote typical and maximum DCR?
A guaranteed thermal design uses the maximum. A nominal efficiency calculation uses the typical. Publishing both lets the same table serve either purpose.
How much inductance is left at rated current?
That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.
Shenzhen Gaorunxin Technology Co., Ltd