    HCM1104-R36-R at a glance: molded high-current power inductor, 0.36 uH ±20%, 30 A Irms, Isat 42 A (20% rolloff @ +25 °C), DCR 1.04 mOhm, 11.5 x 10.3 mm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberHCM1104-R36-R
    OCL (open circuit inductance)0.36 uH ±20%
    FLL minimum, at Isat0.23 uH
    Irms (DC, 40 °C rise)30 A
    Isat (20% rolloff @ +25 °C)42 A
    DCR typical @ +20 °C1.04 mOhm
    DCR maximum @ +20 °C1.2 mOhm
    K-factor (Bp-p = K x L x dI)269, Bp-p in Gauss
    Package11.5 x 10.3 mm
    Height4.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4370

    Mechanical Dimensions & Pad Layout

    HCM1104-R36-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4370: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    This is one of the molded power inductors used across VRM, point-of-load and multiphase regulator designs. The family covers a wide inductance range in standard footprints, and every row is characterised for both typical and maximum DCR so the loss budget can be built either way.

    Copper loss at the rated current works out to roughly 0.936 W from a typical DCR of 1.04 mOhm at 30 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    Stored energy at Isat is about 318 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.

    The K-factor of 269 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 96.8 Gauss of Bp-p, the figure the core-loss curve is plotted against.

    What This Family Is For

    The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.

    In the HCM1104 line-up this part is number 2 of 12 by inductance, between 0.2 uH and 22 uH.

    The next value up in the same family, HCM1104-R45-R, gives 0.45 uH at 29 A and DCR 1.07 mOhm: the extra inductance costs about 3 A of rated current.

    • Core material: iron powder core, 11.5 x 10.3 mm body at 4.0 mm.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; point-of-load modules; desktop and server vrms and evrds; base station equipment; notebook and laptop regulators.
    • The DCR columns are typical and maximum at +20 °C. Copper rises about 0.4 % per °C, so the hot resistance is higher than either column suggests.

    Design Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 1.2 mOhm becomes roughly 1.7 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.

    • Allow for copper drift: resistance rises with temperature at roughly 0.4 % per °C.
    • Build the thermal design on the maximum DCR, not the typical one.
    • Allow for copper drift: resistance rises with temperature at roughly 0.4 % per °C.

    Frequently Asked Questions

    How much inductance is left at rated current?
    That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.

    What makes a molded inductor different?
    The winding is pressed into the magnetic powder with no bobbin or air gap in the path. That is why the body is almost all magnetic material, the DCR is low for the size, and the part is mechanically robust.

    What makes a molded inductor different?
    The winding is pressed into the magnetic powder with no bobbin or air gap in the path. That is why the body is almost all magnetic material, the DCR is low for the size, and the part is mechanically robust.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products