| Parameter | Value |
|---|---|
| Orderable part number | HCM1104-R36-R |
| OCL (open circuit inductance) | 0.36 uH ±20% |
| FLL minimum, at Isat | 0.23 uH |
| Irms (DC, 40 °C rise) | 30 A |
| Isat (20% rolloff @ +25 °C) | 42 A |
| DCR typical @ +20 °C | 1.04 mOhm |
| DCR maximum @ +20 °C | 1.2 mOhm |
| K-factor (Bp-p = K x L x dI) | 269, Bp-p in Gauss |
| Package | 11.5 x 10.3 mm |
| Height | 4.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4370 |

Drawing reproduced from Eaton Technical Data 4370: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
This is one of the molded power inductors used across VRM, point-of-load and multiphase regulator designs. The family covers a wide inductance range in standard footprints, and every row is characterised for both typical and maximum DCR so the loss budget can be built either way.
Copper loss at the rated current works out to roughly 0.936 W from a typical DCR of 1.04 mOhm at 30 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.
Stored energy at Isat is about 318 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.
The K-factor of 269 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 96.8 Gauss of Bp-p, the figure the core-loss curve is plotted against.
The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.
In the HCM1104 line-up this part is number 2 of 12 by inductance, between 0.2 uH and 22 uH.
The next value up in the same family, HCM1104-R45-R, gives 0.45 uH at 29 A and DCR 1.07 mOhm: the extra inductance costs about 3 A of rated current.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 1.2 mOhm becomes roughly 1.7 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.
How much inductance is left at rated current?
That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.
What makes a molded inductor different?
The winding is pressed into the magnetic powder with no bobbin or air gap in the path. That is why the body is almost all magnetic material, the DCR is low for the size, and the part is mechanically robust.
What makes a molded inductor different?
The winding is pressed into the magnetic powder with no bobbin or air gap in the path. That is why the body is almost all magnetic material, the DCR is low for the size, and the part is mechanically robust.
Shenzhen Gaorunxin Technology Co., Ltd