Eaton HCM1104-R45-R 0.45 uH Molded Power Inductor, 29 A
Eaton HCM1104-R45-R 0.45 uH Molded Power Inductor, 29 A

Eaton HCM1104-R45-R 0.45 uH Molded Power Inductor, 29 A

Share
Eaton HCM1104-R45-R: molded high-current power inductor, 0.45 uH ±20%, 29 A Irms, Isat 36 A, DCR 1.07 mOhm, 11.5 x 10.3 mm.
    • Product Details
    • Download

    Eaton HCM1104-R45-R 0.45 uH Molded Power Inductor, 29 A

    HCM1104-R45-R at a glance: molded high-current power inductor, 0.45 uH ±20%, 29 A Irms, Isat 36 A (20% rolloff @ +25 °C), DCR 1.07 mOhm, 11.5 x 10.3 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHCM1104-R45-R
    OCL (open circuit inductance)0.45 uH ±20%
    FLL minimum, at Isat0.29 uH
    Irms (DC, 40 °C rise)29 A
    Isat (20% rolloff @ +25 °C)36 A
    DCR typical @ +20 °C1.07 mOhm
    DCR maximum @ +20 °C1.23 mOhm
    K-factor (Bp-p = K x L x dI)219, Bp-p in Gauss
    Package11.5 x 10.3 mm
    Height4.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4370

    Mechanical Dimensions & Pad Layout

    HCM1104-R45-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4370: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    A molded body around an alloy or iron powder core: the winding is pressed into the magnetic material, so the field is contained inside the part and the terminals come straight out of the molding. The result is a shielded inductor with a low profile and a soft saturation curve, on a footprint that is almost all magnetic material.

    The DCR figure of 1.07 mOhm is what sets the efficiency: at 29 A the winding drops about 0.031 mV and dissipates 0.9 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.

    The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    Stored energy at Isat is about 292 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.

    With K = 219, a peak-to-peak ripple of one amp produces roughly 98.5 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Positioning in the Range

    The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.

    Within the HCM1104 family this is value 3 of 12, in a range that runs from 0.2 uH to 22 uH.

    Compared with its neighbours in the table, HCM1104-R56-R trades 5 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: iron powder core, 11.5 x 10.3 mm body at 4.0 mm.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; point-of-load modules; desktop and server vrms and evrds; base station equipment; notebook and laptop regulators.
    • The DCR columns are typical and maximum at +20 °C. Copper rises about 0.4 % per °C, so the hot resistance is higher than either column suggests.

    Design Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 1.23 mOhm becomes roughly 1.74 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.

    • Allow for copper drift: resistance rises with temperature at roughly 0.4 % per °C.
    • Verify the body height against the enclosure or heat-spreader clearance.
    • Check the hot DCR before signing off the efficiency budget.

    Frequently Asked Questions

    What makes a molded inductor different?
    The winding is pressed into the magnetic powder with no bobbin or air gap in the path. That is why the body is almost all magnetic material, the DCR is low for the size, and the part is mechanically robust.

    How much inductance is left at rated current?
    That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.

    Why quote typical and maximum DCR?
    A guaranteed thermal design uses the maximum. A nominal efficiency calculation uses the typical. Publishing both lets the same table serve either purpose.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products