Eaton HCM1305-150-R 15.0 uH High-Current Inductor 29 mOhm
Eaton HCM1305-150-R 15.0 uH High-Current Inductor 29 mOhm

Eaton HCM1305-150-R 15.0 uH High-Current Inductor 29 mOhm

Share
Eaton HCM1305-150-R: molded high-current power inductor, 15.0 uH ±20%, 7.7 A Irms, Isat 13 A, DCR 29 mOhm, 13.8 x 12.5 mm.
    • Product Details
    • Download

    Eaton HCM1305-150-R 15.0 uH High-Current Inductor 29 mOhm

    HCM1305-150-R at a glance: molded high-current power inductor, 15.0 uH ±20%, 7.7 A Irms, Isat 13 A (20% rolloff @ +25 °C), DCR 29 mOhm, 13.8 x 12.5 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHCM1305-150-R
    OCL (open circuit inductance)15.0 uH ±20%
    FLL minimum, at Isat9.6 uH
    Irms (DC, 40 °C rise)7.7 A
    Isat (20% rolloff @ +25 °C)13 A
    DCR typical @ +20 °C29 mOhm
    DCR maximum @ +20 °C33.4 mOhm
    K-factor (Bp-p = K x L x dI)74, Bp-p in Gauss
    Package13.8 x 12.5 mm
    Height5.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4371

    Dimensions and Pad Layout

    HCM1305-150-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4371: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    Molded construction is what gives this family its mechanical robustness and its shielding. Because the core surrounds the winding on all sides, the leakage field that would otherwise couple into adjacent traces is small, and the part can be placed close to sensitive nodes.

    At the rated 7.7 A the winding dissipates about 1.72 W in copper alone, using the typical DCR of 29 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.

    The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    Energy storage at the saturation current is around 1,268 uJ, the number that connects the inductance and the current rating into a single transient figure.

    With K = 74, a peak-to-peak ripple of one amp produces roughly 1,110 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    What This Family Is For

    The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.

    Within the HCM1305 family this is value 19 of 21, in a range that runs from 0.1 uH to 33 uH.

    One step down the table, HCM1305-100-R, sits at 10.0 uH with 9 A and 19 mOhm – the lower inductance buys about 2.8 A of extra current in the same body.

    • Core material: iron powder core, 13.8 x 12.5 mm body at 5.0 mm.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; point-of-load modules; desktop and server vrms and evrds; base station equipment; notebook and laptop regulators.
    • The DCR columns are typical and maximum at +20 °C. Copper rises about 0.4 % per °C, so the hot resistance is higher than either column suggests.

    Putting It to Work

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 33.4 mOhm becomes roughly 47.2 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.

    • Check the hot DCR before signing off the efficiency budget.
    • Verify the body height against the enclosure or heat-spreader clearance.
    • Check the hot DCR before signing off the efficiency budget.

    Frequently Asked Questions

    What makes a molded inductor different?
    The winding is pressed into the magnetic powder with no bobbin or air gap in the path. That is why the body is almost all magnetic material, the DCR is low for the size, and the part is mechanically robust.

    How much does the inductance drop at rated current?
    That is what the Isat column quantifies. At the rated DC current the part is still inside the rolloff boundary, but the ripple calculation should use the FLL column rather than OCL.

    How much inductance is left at rated current?
    That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.