| Parameter | Value |
|---|---|
| Orderable part number | HCM1305-150-R |
| OCL (open circuit inductance) | 15.0 uH ±20% |
| FLL minimum, at Isat | 9.6 uH |
| Irms (DC, 40 °C rise) | 7.7 A |
| Isat (20% rolloff @ +25 °C) | 13 A |
| DCR typical @ +20 °C | 29 mOhm |
| DCR maximum @ +20 °C | 33.4 mOhm |
| K-factor (Bp-p = K x L x dI) | 74, Bp-p in Gauss |
| Package | 13.8 x 12.5 mm |
| Height | 5.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4371 |

Drawing reproduced from Eaton Technical Data 4371: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Molded construction is what gives this family its mechanical robustness and its shielding. Because the core surrounds the winding on all sides, the leakage field that would otherwise couple into adjacent traces is small, and the part can be placed close to sensitive nodes.
At the rated 7.7 A the winding dissipates about 1.72 W in copper alone, using the typical DCR of 29 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.
The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.
Energy storage at the saturation current is around 1,268 uJ, the number that connects the inductance and the current rating into a single transient figure.
With K = 74, a peak-to-peak ripple of one amp produces roughly 1,110 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.
The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.
Within the HCM1305 family this is value 19 of 21, in a range that runs from 0.1 uH to 33 uH.
One step down the table, HCM1305-100-R, sits at 10.0 uH with 9 A and 19 mOhm – the lower inductance buys about 2.8 A of extra current in the same body.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 33.4 mOhm becomes roughly 47.2 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.
What makes a molded inductor different?
The winding is pressed into the magnetic powder with no bobbin or air gap in the path. That is why the body is almost all magnetic material, the DCR is low for the size, and the part is mechanically robust.
How much does the inductance drop at rated current?
That is what the Isat column quantifies. At the rated DC current the part is still inside the rolloff boundary, but the ripple calculation should use the FLL column rather than OCL.
How much inductance is left at rated current?
That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd