| Parameter | Value |
|---|---|
| Orderable part number | HCM1305-1R8-R |
| OCL (open circuit inductance) | 1.80 uH ±20% |
| FLL minimum, at Isat | 1.15 uH |
| Irms (DC, 40 °C rise) | 21 A |
| Isat (20% rolloff @ +25 °C) | 40 A |
| DCR typical @ +20 °C | 4 mOhm |
| DCR maximum @ +20 °C | 4.6 mOhm |
| K-factor (Bp-p = K x L x dI) | 216, Bp-p in Gauss |
| Package | 13.8 x 12.5 mm |
| Height | 5.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4371 |

Drawing reproduced from Eaton Technical Data 4371: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
A molded body around an alloy or iron powder core: the winding is pressed into the magnetic material, so the field is contained inside the part and the terminals come straight out of the molding. The result is a shielded inductor with a low profile and a soft saturation curve, on a footprint that is almost all magnetic material.
At the rated 21 A the winding dissipates about 1.76 W in copper alone, using the typical DCR of 4 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.
Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.
The core stores roughly 1,440 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.
The K-factor of 216 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 389 Gauss of Bp-p, the figure the core-loss curve is plotted against.
The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.
Of the 21 values listed for HCM1305, this is the 10th, in a family covering 0.1 uH to 33 uH.
The next value up in the same family, HCM1305-2R2-R, gives 2.20 uH at 20 A and DCR 4.6 mOhm: the extra inductance costs about 3 A of rated current.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 4.6 mOhm becomes roughly 6.5 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.
What makes a molded inductor different?
The winding is pressed into the magnetic powder with no bobbin or air gap in the path. That is why the body is almost all magnetic material, the DCR is low for the size, and the part is mechanically robust.
What makes a molded inductor different?
The winding is pressed into the magnetic powder with no bobbin or air gap in the path. That is why the body is almost all magnetic material, the DCR is low for the size, and the part is mechanically robust.
What makes a molded inductor different?
The winding is pressed into the magnetic powder with no bobbin or air gap in the path. That is why the body is almost all magnetic material, the DCR is low for the size, and the part is mechanically robust.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd