| Parameter | Value |
|---|---|
| Orderable part number | HCM1305-3R3-R |
| OCL (open circuit inductance) | 3.30 uH ±20% |
| FLL minimum, at Isat | 2.11 uH |
| Irms (DC, 40 °C rise) | 15 A |
| Isat (20% rolloff @ +25 °C) | 32 A |
| DCR typical @ +20 °C | 7.7 mOhm |
| DCR maximum @ +20 °C | 9.2 mOhm |
| K-factor (Bp-p = K x L x dI) | 170, Bp-p in Gauss |
| Package | 13.8 x 12.5 mm |
| Height | 5.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4371 |

Drawing reproduced from Eaton Technical Data 4371: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
The part is a surface-mount molded inductor: powder core, directly wound and pressed, with the terminals formed from the winding ends. The absence of a bobbin or an air gap in the magnetic path is what keeps the DCR low for the current rating, and the soft saturation is a property of the distributed gap.
Copper loss at the rated current works out to roughly 1.73 W from a typical DCR of 7.7 mOhm at 15 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.
Stored energy at Isat is about 1,690 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.
With K = 170, a peak-to-peak ripple of one amp produces roughly 561 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.
The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.
In the HCM1305 line-up this part is number 12 of 21 by inductance, between 0.1 uH and 33 uH.
The next value up in the same family, HCM1305-4R7-R, gives 4.70 uH at 12 A and DCR 11 mOhm: the extra inductance costs about 8 A of rated current.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 9.2 mOhm becomes roughly 13 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.
How much inductance is left at rated current?
That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.
Why quote typical and maximum DCR?
A guaranteed thermal design uses the maximum. A nominal efficiency calculation uses the typical. Publishing both lets the same table serve either purpose.
Why quote typical and maximum DCR?
A guaranteed thermal design uses the maximum. A nominal efficiency calculation uses the typical. Publishing both lets the same table serve either purpose.