Eaton HCM1305-5R6-R Molded Inductor 5.60 uH, Isat 22 A
Eaton HCM1305-5R6-R Molded Inductor 5.60 uH, Isat 22 A

Eaton HCM1305-5R6-R Molded Inductor 5.60 uH, Isat 22 A

Share
Eaton HCM1305-5R6-R: molded high-current power inductor, 5.60 uH ±20%, 11.5 A Irms, Isat 22 A, DCR 12 mOhm, 13.8 x 12.5 mm.
    • Product Details
    • Download

    Eaton HCM1305-5R6-R Molded Inductor 5.60 uH, Isat 22 A

    HCM1305-5R6-R at a glance: molded high-current power inductor, 5.60 uH ±20%, 11.5 A Irms, Isat 22 A (20% rolloff @ +25 °C), DCR 12 mOhm, 13.8 x 12.5 mm.

    Specification Table

    ParameterValue
    Orderable part numberHCM1305-5R6-R
    OCL (open circuit inductance)5.60 uH ±20%
    FLL minimum, at Isat3.58 uH
    Irms (DC, 40 °C rise)11.5 A
    Isat (20% rolloff @ +25 °C)22 A
    DCR typical @ +20 °C12 mOhm
    DCR maximum @ +20 °C13.8 mOhm
    K-factor (Bp-p = K x L x dI)142, Bp-p in Gauss
    Package13.8 x 12.5 mm
    Height5.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4371

    Mechanical Dimensions & Pad Layout

    HCM1305-5R6-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4371: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    A molded body around an alloy or iron powder core: the winding is pressed into the magnetic material, so the field is contained inside the part and the terminals come straight out of the molding. The result is a shielded inductor with a low profile and a soft saturation curve, on a footprint that is almost all magnetic material.

    At the rated 11.5 A the winding dissipates about 1.59 W in copper alone, using the typical DCR of 12 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.

    Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.

    The core stores roughly 1,355 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.

    K-factor 142 means the flux swing is about 795 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    Where This Series Fits

    The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.

    The HCM1305 family spans 0.1 uH to 33 uH; this row sits at position 14 of 21.

    One step down the table, HCM1305-4R7-R, sits at 4.70 uH with 12 A and 11 mOhm – the lower inductance buys about 1 A of extra current in the same body.

    • Core material: iron powder core, 13.8 x 12.5 mm body at 5.0 mm.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; point-of-load modules; desktop and server vrms and evrds; base station equipment; notebook and laptop regulators.
    • The DCR columns are typical and maximum at +20 °C. Copper rises about 0.4 % per °C, so the hot resistance is higher than either column suggests.

    Sizing and Layout Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 13.8 mOhm becomes roughly 19.5 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.

    • Check the hot DCR before signing off the efficiency budget.
    • Build the thermal design on the maximum DCR, not the typical one.
    • Confirm the peak transient current stays under Isat with tolerance margin.

    Frequently Asked Questions

    Can two parts be stacked for higher current?
    Stacking halves the inductance and doubles the current capability in theory, but the two DCRs are not matched and the magnetic coupling is uncontrolled. Use a larger part instead.

    How much does the inductance drop at rated current?
    That is what the Isat column quantifies. At the rated DC current the part is still inside the rolloff boundary, but the ripple calculation should use the FLL column rather than OCL.

    How much does the inductance drop at rated current?
    That is what the Isat column quantifies. At the rated DC current the part is still inside the rolloff boundary, but the ripple calculation should use the FLL column rather than OCL.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products