| Parameter | Value |
|---|---|
| Orderable part number | HCM1305-6R8-R |
| OCL (open circuit inductance) | 6.80 uH ±20% |
| FLL minimum, at Isat | 4.35 uH |
| Irms (DC, 40 °C rise) | 11 A |
| Isat (20% rolloff @ +25 °C) | 21 A |
| DCR typical @ +20 °C | 13 mOhm |
| DCR maximum @ +20 °C | 15 mOhm |
| K-factor (Bp-p = K x L x dI) | 129, Bp-p in Gauss |
| Package | 13.8 x 12.5 mm |
| Height | 5.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4371 |

Drawing reproduced from Eaton Technical Data 4371: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
The part is a surface-mount molded inductor: powder core, directly wound and pressed, with the terminals formed from the winding ends. The absence of a bobbin or an air gap in the magnetic path is what keeps the DCR low for the current rating, and the soft saturation is a property of the distributed gap.
The DCR figure of 13 mOhm is what sets the efficiency: at 11 A the winding drops about 0.143 mV and dissipates 1.57 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.
The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.
The core stores roughly 1,499 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.
The K-factor of 129 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 877 Gauss of Bp-p, the figure the core-loss curve is plotted against.
The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.
Of the 21 values listed for HCM1305, this is the 15th, in a family covering 0.1 uH to 33 uH.
The next value up in the same family, HCM1305-7R8-R, gives 7.80 uH at 10 A and DCR 16.8 mOhm: the extra inductance costs about 1.5 A of rated current.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 15 mOhm becomes roughly 21.2 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.
Can two parts be stacked for higher current?
Stacking halves the inductance and doubles the current capability in theory, but the two DCRs are not matched and the magnetic coupling is uncontrolled. Use a larger part instead.
How much inductance is left at rated current?
That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.
What makes a molded inductor different?
The winding is pressed into the magnetic powder with no bobbin or air gap in the path. That is why the body is almost all magnetic material, the DCR is low for the size, and the part is mechanically robust.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd