Eaton HCM1305-R22-R: molded high-current power inductor, 0.22 uH ±20%, 51 A Irms, Isat 110 A, DCR 0.63 mOhm, 13.8 x 12.5 mm.
    • Product Details
    • Download

    Eaton HCM1305-R22-R Molded Inductor 0.22 uH, Isat 110 A

    HCM1305-R22-R at a glance: molded high-current power inductor, 0.22 uH ±20%, 51 A Irms, Isat 110 A (20% rolloff @ +25 °C), DCR 0.63 mOhm, 13.8 x 12.5 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHCM1305-R22-R
    OCL (open circuit inductance)0.22 uH ±20%
    FLL minimum, at Isat0.14 uH
    Irms (DC, 40 °C rise)51 A
    Isat (20% rolloff @ +25 °C)110 A
    DCR typical @ +20 °C0.63 mOhm
    DCR maximum @ +20 °C0.72 mOhm
    K-factor (Bp-p = K x L x dI)843, Bp-p in Gauss
    Package13.8 x 12.5 mm
    Height5.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4371

    Outline Drawing

    HCM1305-R22-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4371: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    Molded construction is what gives this family its mechanical robustness and its shielding. Because the core surrounds the winding on all sides, the leakage field that would otherwise couple into adjacent traces is small, and the part can be placed close to sensitive nodes.

    Copper loss at the rated current works out to roughly 1.64 W from a typical DCR of 0.63 mOhm at 51 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.

    At Isat the part holds about 1,331 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.

    The K-factor of 843 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 186 Gauss of Bp-p, the figure the core-loss curve is plotted against.

    Where This Series Fits

    The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.

    In the HCM1305 line-up this part is number 2 of 21 by inductance, between 0.1 uH and 33 uH.

    One step down the table, HCM1305-R10-R, sits at 0.10 uH with 55 A and 0.52 mOhm – the lower inductance buys about 13 A of extra current in the same body.

    • Core material: iron powder core, 13.8 x 12.5 mm body at 5.0 mm.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; point-of-load modules; desktop and server vrms and evrds; base station equipment; notebook and laptop regulators.
    • The DCR columns are typical and maximum at +20 °C. Copper rises about 0.4 % per °C, so the hot resistance is higher than either column suggests.

    Design Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 0.72 mOhm becomes roughly 1.02 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.

    • Build the thermal design on the maximum DCR, not the typical one.
    • Confirm the peak transient current stays under Isat with tolerance margin.
    • Confirm the shielding is adequate for the adjacent trace routing.

    Frequently Asked Questions

    What makes a molded inductor different?
    The winding is pressed into the magnetic powder with no bobbin or air gap in the path. That is why the body is almost all magnetic material, the DCR is low for the size, and the part is mechanically robust.

    Why quote typical and maximum DCR?
    A guaranteed thermal design uses the maximum. A nominal efficiency calculation uses the typical. Publishing both lets the same table serve either purpose.

    Is it magnetically shielded?
    Yes. The powder core surrounds the winding, so the leakage field is small and the part can sit close to sensitive traces without a shield can.