
| Parameter | Value |
|---|---|
| Orderable part number | HCM1305-R33-R |
| OCL (open circuit inductance) | 0.33 uH ±20% |
| FLL minimum, at Isat | 0.21 uH |
| Irms (DC, 40 °C rise) | 42 A |
| Isat (20% rolloff @ +25 °C) | 80 A |
| DCR typical @ +20 °C | 0.8 mOhm |
| DCR maximum @ +20 °C | 0.92 mOhm |
| K-factor (Bp-p = K x L x dI) | 506, Bp-p in Gauss |
| Package | 13.8 x 12.5 mm |
| Height | 5.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4371 |

Drawing reproduced from Eaton Technical Data 4371: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
This is one of the molded power inductors used across VRM, point-of-load and multiphase regulator designs. The family covers a wide inductance range in standard footprints, and every row is characterised for both typical and maximum DCR so the loss budget can be built either way.
At the rated 42 A the winding dissipates about 1.41 W in copper alone, using the typical DCR of 0.8 mOhm. That figure is the floor of the loss budget: it assumes the current is pure DC, and any ripple adds to it.
The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.
The core stores roughly 1,056 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.
The K-factor of 506 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 167 Gauss of Bp-p, the figure the core-loss curve is plotted against.
The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.
The HCM1305 family spans 0.1 uH to 33 uH; this row sits at position 3 of 21.
One step down the table, HCM1305-R22-R, sits at 0.22 uH with 51 A and 0.63 mOhm – the lower inductance buys about 13 A of extra current in the same body.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 0.92 mOhm becomes roughly 1.3 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.
Can two parts be stacked for higher current?
Stacking halves the inductance and doubles the current capability in theory, but the two DCRs are not matched and the magnetic coupling is uncontrolled. Use a larger part instead.
How much does the inductance drop at rated current?
That is what the Isat column quantifies. At the rated DC current the part is still inside the rolloff boundary, but the ripple calculation should use the FLL column rather than OCL.
What makes a molded inductor different?
The winding is pressed into the magnetic powder with no bobbin or air gap in the path. That is why the body is almost all magnetic material, the DCR is low for the size, and the part is mechanically robust.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd