Eaton HCM1307-R47-R Molded Inductor 0.47 uH, Isat 63 A
Eaton HCM1307-R47-R Molded Inductor 0.47 uH, Isat 63 A

Eaton HCM1307-R47-R Molded Inductor 0.47 uH, Isat 63 A

Share
Eaton HCM1307-R47-R: molded high-current power inductor, 0.47 uH ±20%, 38 A Irms, Isat 63 A, DCR 1 mOhm, 14.2 x 13 mm.
    • Product Details
    • Download

    Eaton HCM1307-R47-R Molded Inductor 0.47 uH, Isat 63 A

    HCM1307-R47-R at a glance: molded high-current power inductor, 0.47 uH ±20%, 38 A Irms, Isat 63 A (20% rolloff @ +25 °C), DCR 1 mOhm, 14.2 x 13 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHCM1307-R47-R
    OCL (open circuit inductance)0.47 uH ±20%
    FLL minimum, at Isat0.26 uH
    Irms (DC, 40 °C rise)38 A
    Isat (20% rolloff @ +25 °C)63 A
    DCR typical @ +20 °C1 mOhm
    DCR maximum @ +20 °C1.2 mOhm
    K-factor (Bp-p = K x L x dI)192, Bp-p in Gauss
    Package14.2 x 13 mm
    Height6.5 mm
    MountingSurface mount
    Operating temperature-55 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10433

    Mechanical Dimensions & Pad Layout

    HCM1307-R47-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10433: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    A molded body around an alloy or iron powder core: the winding is pressed into the magnetic material, so the field is contained inside the part and the terminals come straight out of the molding. The result is a shielded inductor with a low profile and a soft saturation curve, on a footprint that is almost all magnetic material.

    Copper loss at the rated current works out to roughly 1.44 W from a typical DCR of 1 mOhm at 38 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    The core stores roughly 933 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.

    K-factor 192 means the flux swing is about 90.2 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    What This Family Is For

    The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.

    The HCM1307 family spans 0.47 uH to 3.3 uH; this row sits at position 1 of 3.

    The next value up in the same family, HCM1307-1R0-R, gives 1.0 uH at 29 A and DCR 1.7 mOhm: the extra inductance costs about 0 A of rated current.

    • Core material: iron powder core, 14.2 x 13 mm body at 6.5 mm.
    • Typical applications: multi-phase regulators; voltage regulator modules (vrms); distributed power systems dc-dc converters; desktop and server vrms and evrds; point-of-load (pol) modules; field programmable gate array (fpga) dc-dc converters.
    • The DCR columns are typical and maximum at +20 °C. Copper rises about 0.4 % per °C, so the hot resistance is higher than either column suggests.

    Putting It to Work

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 1.2 mOhm becomes roughly 1.7 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.

    • Allow for copper drift: resistance rises with temperature at roughly 0.4 % per °C.
    • Check the hot DCR before signing off the efficiency budget.
    • Verify the body height against the enclosure or heat-spreader clearance.

    Frequently Asked Questions

    How much does the inductance drop at rated current?
    That is what the Isat column quantifies. At the rated DC current the part is still inside the rolloff boundary, but the ripple calculation should use the FLL column rather than OCL.

    Why quote typical and maximum DCR?
    A guaranteed thermal design uses the maximum. A nominal efficiency calculation uses the typical. Publishing both lets the same table serve either purpose.

    How much does the inductance drop at rated current?
    That is what the Isat column quantifies. At the rated DC current the part is still inside the rolloff boundary, but the ripple calculation should use the FLL column rather than OCL.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products