| Parameter | Value |
|---|---|
| Orderable part number | HCM1707-100-R |
| OCL (open circuit inductance) | 10 uH ±20% |
| FLL minimum, at Isat | 6.4 uH |
| Irms (DC, 40 °C rise) | 14 A |
| Isat (20% rolloff @ +25 °C) | 18 A |
| DCR typical @ +20 °C | 9.3 mOhm |
| DCR maximum @ +20 °C | 10 mOhm |
| K-factor (Bp-p = K x L x dI) | 47, Bp-p in Gauss |
| Package | 17.5 x 17.2 mm |
| Height | 7.0 mm |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C (ambient plus self-heating) |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10295 |

Drawing reproduced from Eaton Technical Data 10295: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Molded construction is what gives this family its mechanical robustness and its shielding. Because the core surrounds the winding on all sides, the leakage field that would otherwise couple into adjacent traces is small, and the part can be placed close to sensitive nodes.
With 9.3 mOhm typical, the I-squared-R loss at the full 14 A rating is about 1.82 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.
The Isat column is 20% rolloff @ +25 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.
Energy storage at the saturation current is around 1,620 uJ, the number that connects the inductance and the current rating into a single transient figure.
K-factor 47 means the flux swing is about 470 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.
The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.
In the HCM1707 line-up this part is number 6 of 11 by inductance, between 1.5 uH and 68 uH.
The next value up in the same family, HCM1707-150-R, gives 15 uH at 12 A and DCR 14.5 mOhm: the extra inductance costs about 4 A of rated current.
Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 10 mOhm becomes roughly 14.1 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.
How much inductance is left at rated current?
That is what the saturation column describes. Isat is the peak current at which inductance has fallen by the stated percentage, so at the rated DC current the part is still inside that boundary.
Is it magnetically shielded?
Yes. The powder core surrounds the winding, so the leakage field is small and the part can sit close to sensitive traces without a shield can.
Can two parts be stacked for higher current?
Stacking halves the inductance and doubles the current capability in theory, but the two DCRs are not matched and the magnetic coupling is uncontrolled. Use a larger part instead.