Eaton HCM1707-6R8-R Molded Inductor 6.8 uH, Isat 22 A
Eaton HCM1707-6R8-R Molded Inductor 6.8 uH, Isat 22 A

Eaton HCM1707-6R8-R Molded Inductor 6.8 uH, Isat 22 A

Share
Eaton HCM1707-6R8-R: molded high-current power inductor, 6.8 uH ±20%, 20 A Irms, Isat 22 A, DCR 6.55 mOhm, 17.5 x 17.2 mm.
    • Product Details
    • Download

    Eaton HCM1707-6R8-R Molded Inductor 6.8 uH, Isat 22 A

    HCM1707-6R8-R at a glance: molded high-current power inductor, 6.8 uH ±20%, 20 A Irms, Isat 22 A (20% rolloff @ +25 °C), DCR 6.55 mOhm, 17.5 x 17.2 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHCM1707-6R8-R
    OCL (open circuit inductance)6.8 uH ±20%
    FLL minimum, at Isat4.35 uH
    Irms (DC, 40 °C rise)20 A
    Isat (20% rolloff @ +25 °C)22 A
    DCR typical @ +20 °C6.55 mOhm
    DCR maximum @ +20 °C7.55 mOhm
    K-factor (Bp-p = K x L x dI)60, Bp-p in Gauss
    Package17.5 x 17.2 mm
    Height7.0 mm
    MountingSurface mount
    Operating temperature-40 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10295

    Dimensions and Pad Layout

    HCM1707-6R8-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10295: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    This is one of the molded power inductors used across VRM, point-of-load and multiphase regulator designs. The family covers a wide inductance range in standard footprints, and every row is characterised for both typical and maximum DCR so the loss budget can be built either way.

    With 6.55 mOhm typical, the I-squared-R loss at the full 20 A rating is about 2.62 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.

    Energy storage at the saturation current is around 1,646 uJ, the number that connects the inductance and the current rating into a single transient figure.

    K-factor 60 means the flux swing is about 408 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    Series Positioning

    The HCM family is the commercial molded range: shielded powder-core parts from a 5.5 mm footprint up to a 17.5 mm body, covering 0.1 uH to tens of microhenry at currents from a few amps to over a hundred.

    Within the HCM1707 family this is value 4 of 11, in a range that runs from 1.5 uH to 68 uH.

    The next value up in the same family, HCM1707-8R2-R, gives 8.2 uH at 16 A and DCR 8.1 mOhm: the extra inductance costs about 11 A of rated current.

    • Core material: iron powder core, 17.5 x 17.2 mm body at 7.0 mm.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; point-of-load modules; desktop and server vrms and evrds; data networking and storage systems; base station equipment.
    • The DCR columns are typical and maximum at +20 °C. Copper rises about 0.4 % per °C, so the hot resistance is higher than either column suggests.

    Putting It to Work

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 7.55 mOhm becomes roughly 10.7 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: two DCR columns let the loss budget be built either on the typical part or on the worst-case part. Use maximum for a guaranteed thermal design, typical for a nominal one.

    • Confirm the peak transient current stays under Isat with tolerance margin.
    • Confirm the shielding is adequate for the adjacent trace routing.
    • Check the hot DCR before signing off the efficiency budget.

    Frequently Asked Questions

    How much does the inductance drop at rated current?
    That is what the Isat column quantifies. At the rated DC current the part is still inside the rolloff boundary, but the ripple calculation should use the FLL column rather than OCL.

    Can two parts be stacked for higher current?
    Stacking halves the inductance and doubles the current capability in theory, but the two DCRs are not matched and the magnetic coupling is uncontrolled. Use a larger part instead.

    Can two parts be stacked for higher current?
    Stacking halves the inductance and doubles the current capability in theory, but the two DCRs are not matched and the magnetic coupling is uncontrolled. Use a larger part instead.

    Shenzhen Gaorunxin Technology Co., Ltd