Eaton HCM1A0503-1R5-R: AEC-Q200 automotive power inductor, 1.5 uH ±20%, 5.2 A Irms, Isat 6.8 A, DCR 17.1 mOhm, 5.5 x 5.3 mm.
    • Product Details
    • Download

    Eaton HCM1A0503-1R5-R 1.5 uH AEC-Q200 Inductor, 5.2 A

    HCM1A0503-1R5-R at a glance: AEC-Q200 automotive power inductor, 1.5 uH ±20%, 5.2 A Irms, Isat 6.8 A (20% rolloff @ +25 °C), DCR 17.1 mOhm, 5.5 x 5.3 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHCM1A0503-1R5-R
    OCL (open circuit inductance)1.5 uH ±20%
    FLL minimum, at Isat0.96 uH
    Irms (DC, 40 °C rise)5.2 A
    Isat (20% rolloff @ +25 °C)6.8 A
    DCR typical @ +20 °C17.1 mOhm
    DCR maximum @ +20 °C18.5 mOhm
    K-factor (Bp-p = K x L x dI)450, Bp-p in Gauss
    Package5.5 x 5.3 mm
    Height3.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10547

    Dimensions and Pad Layout

    HCM1A0503-1R5-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10547: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.

    With 17.1 mOhm typical, the I-squared-R loss at the full 5.2 A rating is about 0.462 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    Energy storage at the saturation current is around 34.7 uJ, the number that connects the inductance and the current rating into a single transient figure.

    K-factor 450 means the flux swing is about 675 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    Positioning in the Range

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    Within the HCM1A0503 family this is value 9 of 15, in a range that runs from 0.2 uH to 10 uH.

    The next value up in the same family, HCM1A0503-2R2-R, gives 2.2 uH at 4.5 A and DCR 22.5 mOhm: the extra inductance costs about 2.6 A of rated current.

    • Core material: alloy powder core, 5.5 x 5.3 mm body at 3.0 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tail lamps and interior lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Sizing and Layout Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 18.5 mOhm becomes roughly 28.3 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Confirm the qualification file covers the module-level test plan.
    • Confirm the revision letter (base / V2 / V3) before comparing electrical rows.
    • Confirm the qualification file covers the module-level test plan.

    Frequently Asked Questions

    Does the automotive grade change the electrical values?
    Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.

    What is the self-resonant frequency used for?
    It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.

    What is the self-resonant frequency used for?
    It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products