| Parameter | Value |
|---|---|
| Orderable part number | HCM1A0503-5R6-R |
| OCL (open circuit inductance) | 5.6 uH ±20% |
| FLL minimum, at Isat | 3.6 uH |
| Irms (DC, 40 °C rise) | 2.8 A |
| Isat (20% rolloff @ +25 °C) | 4 A |
| DCR typical @ +20 °C | 63 mOhm |
| DCR maximum @ +20 °C | 70.6 mOhm |
| K-factor (Bp-p = K x L x dI) | 235, Bp-p in Gauss |
| Package | 5.5 x 5.3 mm |
| Height | 3.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10547 |

Drawing reproduced from Eaton Technical Data 10547: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Molded, shielded, AEC-Q200: the family is built for under-hood and in-cabin electronics where the ambient can reach 125 °C and the board cannot afford a radiating inductor. Soft saturation means the transient current does not disappear the inductance, and the shielding keeps the switching harmonics off nearby sensor wiring.
Copper loss at the rated current works out to roughly 0.494 W from a typical DCR of 63 mOhm at 2.8 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.
The core stores roughly 44.8 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.
The K-factor of 235 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 1,316 Gauss of Bp-p, the figure the core-loss curve is plotted against.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
The HCM1A0503 family spans 0.2 uH to 10 uH; this row sits at position 13 of 15.
One step down the table, HCM1A0503-4R7-R, sits at 4.7 uH with 3.1 A and 54 mOhm – the lower inductance buys about 0.8 A of extra current in the same body.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 70.6 mOhm becomes roughly 108 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
What is the self-resonant frequency used for?
It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.
What is the operating temperature range?
The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.
What does AEC-Q200 cover?
The qualification regime for passive components in automotive use: thermal shock, temperature cycling, vibration, mechanical shock, moisture resistance and solderability, among others. It qualifies the construction, not the board design.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd