Eaton HCM1A0503-R22-R 0.22 uH Shielded Automotive Inductor
Eaton HCM1A0503-R22-R 0.22 uH Shielded Automotive Inductor

Eaton HCM1A0503-R22-R 0.22 uH Shielded Automotive Inductor

Share
Eaton HCM1A0503-R22-R: AEC-Q200 automotive power inductor, 0.22 uH ±20%, 15.8 A Irms, Isat 24 A, DCR 2.1 mOhm, 5.5 x 5.3 mm.
    • Product Details
    • Download

    Eaton HCM1A0503-R22-R 0.22 uH Shielded Automotive Inductor

    HCM1A0503-R22-R at a glance: AEC-Q200 automotive power inductor, 0.22 uH ±20%, 15.8 A Irms, Isat 24 A (20% rolloff @ +25 °C), DCR 2.1 mOhm, 5.5 x 5.3 mm.

    Specification Table

    ParameterValue
    Orderable part numberHCM1A0503-R22-R
    OCL (open circuit inductance)0.22 uH ±20%
    FLL minimum, at Isat0.141 uH
    Irms (DC, 40 °C rise)15.8 A
    Isat (20% rolloff @ +25 °C)24 A
    DCR typical @ +20 °C2.1 mOhm
    DCR maximum @ +20 °C2.3 mOhm
    K-factor (Bp-p = K x L x dI)1,004, Bp-p in Gauss
    Package5.5 x 5.3 mm
    Height3.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10547

    Mechanical Drawing

    HCM1A0503-R22-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10547: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    This is the automotive version of the molded high-current inductor. The body is a molded powder core, the winding is shielded by the magnetic material itself, and the operating range runs to +155 °C. It is the part that goes on the DC-DC stages of body electronics, ADAS modules and infotainment head units.

    The DCR figure of 2.1 mOhm is what sets the efficiency: at 15.8 A the winding drops about 0.033 mV and dissipates 0.524 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.

    The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    The core stores roughly 63.4 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.

    With K = 1,004, a peak-to-peak ripple of one amp produces roughly 221 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Positioning in the Range

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    Of the 15 values listed for HCM1A0503, this is the 2th, in a family covering 0.2 uH to 10 uH.

    One step down the table, HCM1A0503-R20-R, sits at 0.20 uH with 15.8 A and 2.1 mOhm – the lower inductance buys about 4 A of extra current in the same body.

    • Core material: alloy powder core, 5.5 x 5.3 mm body at 3.0 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tail lamps and interior lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Sizing and Layout Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 2.3 mOhm becomes roughly 3.52 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Verify the qualification and the mounting process match the assembly line.
    • Confirm the qualification file covers the module-level test plan.
    • Confirm the revision letter (base / V2 / V3) before comparing electrical rows.

    Frequently Asked Questions

    What is the self-resonant frequency used for?
    It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.

    What is the self-resonant frequency used for?
    It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.