Eaton HCM1A0503-R33-R AEC-Q200 Inductor 0.33 uH, Isat 16 A
Eaton HCM1A0503-R33-R AEC-Q200 Inductor 0.33 uH, Isat 16 A

Eaton HCM1A0503-R33-R AEC-Q200 Inductor 0.33 uH, Isat 16 A

Share
Eaton HCM1A0503-R33-R: AEC-Q200 automotive power inductor, 0.33 uH ±20%, 11.8 A Irms, Isat 16 A, DCR 3.9 mOhm, 5.5 x 5.3 mm.
    • Product Details
    • Download

    Eaton HCM1A0503-R33-R AEC-Q200 Inductor 0.33 uH, Isat 16 A

    HCM1A0503-R33-R at a glance: AEC-Q200 automotive power inductor, 0.33 uH ±20%, 11.8 A Irms, Isat 16 A (20% rolloff @ +25 °C), DCR 3.9 mOhm, 5.5 x 5.3 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHCM1A0503-R33-R
    OCL (open circuit inductance)0.33 uH ±20%
    FLL minimum, at Isat0.211 uH
    Irms (DC, 40 °C rise)11.8 A
    Isat (20% rolloff @ +25 °C)16 A
    DCR typical @ +20 °C3.9 mOhm
    DCR maximum @ +20 °C4.3 mOhm
    K-factor (Bp-p = K x L x dI)918, Bp-p in Gauss
    Package5.5 x 5.3 mm
    Height3.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10547

    Mechanical Drawing

    HCM1A0503-R33-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10547: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    Molded, shielded, AEC-Q200: the family is built for under-hood and in-cabin electronics where the ambient can reach 125 °C and the board cannot afford a radiating inductor. Soft saturation means the transient current does not disappear the inductance, and the shielding keeps the switching harmonics off nearby sensor wiring.

    With 3.9 mOhm typical, the I-squared-R loss at the full 11.8 A rating is about 0.543 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    Stored energy at Isat is about 42.2 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.

    With K = 918, a peak-to-peak ripple of one amp produces roughly 303 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    Positioning in the Range

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    The HCM1A0503 family spans 0.2 uH to 10 uH; this row sits at position 3 of 15.

    One step down the table, HCM1A0503-R22-R, sits at 0.22 uH with 15.8 A and 2.1 mOhm – the lower inductance buys about 4 A of extra current in the same body.

    • Core material: alloy powder core, 5.5 x 5.3 mm body at 3.0 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tail lamps and interior lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Design Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 4.3 mOhm becomes roughly 6.58 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Verify the part marking for revision traceability in production.
    • Confirm the revision letter (base / V2 / V3) before comparing electrical rows.
    • Confirm the revision letter (base / V2 / V3) before comparing electrical rows.

    Frequently Asked Questions

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    Is the part shielded for ADAS modules?
    The molded powder core encloses the winding, so the radiated field is small. That is why the family is used next to sensor front ends and camera interfaces.

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products