Eaton HCM1A0503-R35-R: AEC-Q200 automotive power inductor, 0.35 uH ±20%, 11.8 A Irms, Isat 15 A, DCR 3.9 mOhm, 5.5 x 5.3 mm.
    • Product Details
    • Download

    Eaton HCM1A0503-R35-R 0.35 uH Automotive Power Inductor

    HCM1A0503-R35-R at a glance: AEC-Q200 automotive power inductor, 0.35 uH ±20%, 11.8 A Irms, Isat 15 A (20% rolloff @ +25 °C), DCR 3.9 mOhm, 5.5 x 5.3 mm.

    Key Specifications

    ParameterValue
    Orderable part numberHCM1A0503-R35-R
    OCL (open circuit inductance)0.35 uH ±20%
    FLL minimum, at Isat0.224 uH
    Irms (DC, 40 °C rise)11.8 A
    Isat (20% rolloff @ +25 °C)15 A
    DCR typical @ +20 °C3.9 mOhm
    DCR maximum @ +20 °C4.3 mOhm
    K-factor (Bp-p = K x L x dI)914, Bp-p in Gauss
    Package5.5 x 5.3 mm
    Height3.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10547

    Mechanical Drawing

    HCM1A0503-R35-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10547: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.

    Copper loss at the rated current works out to roughly 0.543 W from a typical DCR of 3.9 mOhm at 11.8 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    The core stores roughly 39.4 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.

    K-factor 914 means the flux swing is about 320 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    What This Family Is For

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    Within the HCM1A0503 family this is value 4 of 15, in a range that runs from 0.2 uH to 10 uH.

    Compared with its neighbours in the table, HCM1A0503-R47-R trades 2.6 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: alloy powder core, 5.5 x 5.3 mm body at 3.0 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tail lamps and interior lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Sizing and Layout Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 4.3 mOhm becomes roughly 6.58 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Check Isat and DCR at the hot corner, not at +20 °C.
    • Confirm the qualification file covers the module-level test plan.
    • Verify the qualification and the mounting process match the assembly line.

    Frequently Asked Questions

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    What does AEC-Q200 cover?
    The qualification regime for passive components in automotive use: thermal shock, temperature cycling, vibration, mechanical shock, moisture resistance and solderability, among others. It qualifies the construction, not the board design.

    Does the automotive grade change the electrical values?
    Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.