| Parameter | Value |
|---|---|
| Orderable part number | HCM1A0503-R75-R |
| OCL (open circuit inductance) | 0.75 uH ±20% |
| FLL minimum, at Isat | 0.48 uH |
| Irms (DC, 40 °C rise) | 7.8 A |
| Isat (20% rolloff @ +25 °C) | 12 A |
| DCR typical @ +20 °C | 8.5 mOhm |
| DCR maximum @ +20 °C | 9.4 mOhm |
| K-factor (Bp-p = K x L x dI) | 590, Bp-p in Gauss |
| Package | 5.5 x 5.3 mm |
| Height | 3.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10547 |

Drawing reproduced from Eaton Technical Data 10547: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Automotive power rails ask for two things a commercial inductor does not always give: a qualified construction and a saturation curve that is still usable at the hot corner. The molded powder core here provides both, with AEC-Q200 qualification and a soft rolloff that keeps inductance present at transient peak current.
The DCR figure of 8.5 mOhm is what sets the efficiency: at 7.8 A the winding drops about 0.066 mV and dissipates 0.517 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.
Saturation is quoted as 20% rolloff @ +25 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.
Energy storage at the saturation current is around 54 uJ, the number that connects the inductance and the current rating into a single transient figure.
K-factor 590 means the flux swing is about 442 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
Within the HCM1A0503 family this is value 7 of 15, in a range that runs from 0.2 uH to 10 uH.
One step down the table, HCM1A0503-R68-R, sits at 0.68 uH with 8 A and 8.2 mOhm – the lower inductance buys about 0.9 A of extra current in the same body.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 9.4 mOhm becomes roughly 14.4 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
What does AEC-Q200 cover?
The qualification regime for passive components in automotive use: thermal shock, temperature cycling, vibration, mechanical shock, moisture resistance and solderability, among others. It qualifies the construction, not the board design.
What is the self-resonant frequency used for?
It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.
What is the self-resonant frequency used for?
It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd