| Parameter | Value |
|---|---|
| Orderable part number | HCM1A0503V2-R33-R |
| OCL (open circuit inductance) | 0.33 uH ±20% |
| FLL minimum, at Isat | 0.211 uH |
| Irms (DC, 40 °C rise) | 14 A |
| Isat (20% rolloff @ +25 °C) | 16 A |
| DCR typical @ +20 °C | 2.9 mOhm |
| DCR maximum @ +20 °C | 3.4 mOhm |
| SRF typical | 120 MHz |
| K-factor (Bp-p = K x L x dI) | 1,167, Bp-p in Gauss |
| Package | 5.7 x 5.4 mm |
| Height | 3.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10910 |

Drawing reproduced from Eaton Technical Data 10910: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
AEC-Q200 qualified, molded, magnetically shielded, and rated to +155 °C ambient plus self-heating. The automotive grading is not a label on a commercial part: the test regime covers thermal shock, vibration and moisture, and the data sheet quotes the parameters at the temperature extremes the qualification demands.
Copper loss at the rated current works out to roughly 0.568 W from a typical DCR of 2.9 mOhm at 14 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.
The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.
At Isat the part holds about 42.2 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.
K-factor 1,167 means the flux swing is about 385 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.
Self-resonant frequency is 120 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
The HCM1A0503V2 family spans 0.2 uH to 10 uH; this row sits at position 3 of 15.
One step down the table, HCM1A0503V2-R22-R, sits at 0.22 uH with 15.8 A and 2.1 mOhm – the lower inductance buys about 1.8 A of extra current in the same body.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 3.4 mOhm becomes roughly 5.2 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
Does the automotive grade change the electrical values?
Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.
What is the operating temperature range?
The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.
What is the self-resonant frequency used for?
It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.