    HCM1A0503V2-R47-R at a glance: AEC-Q200 automotive power inductor, 0.47 uH ±20%, 11 A Irms, Isat 12 A (20% rolloff @ +25 °C), DCR 5.3 mOhm, 5.7 x 5.4 mm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHCM1A0503V2-R47-R
    OCL (open circuit inductance)0.47 uH ±20%
    FLL minimum, at Isat0.3 uH
    Irms (DC, 40 °C rise)11 A
    Isat (20% rolloff @ +25 °C)12 A
    DCR typical @ +20 °C5.3 mOhm
    DCR maximum @ +20 °C6.1 mOhm
    SRF typical80 MHz
    K-factor (Bp-p = K x L x dI)867, Bp-p in Gauss
    Package5.7 x 5.4 mm
    Height3.0 mm
    MountingSurface mount
    Operating temperature-55 °C to +155 °C (ambient plus self-heating)
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10910

    Mechanical Dimensions & Pad Layout

    HCM1A0503V2-R47-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10910: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    Automotive power rails ask for two things a commercial inductor does not always give: a qualified construction and a saturation curve that is still usable at the hot corner. The molded powder core here provides both, with AEC-Q200 qualification and a soft rolloff that keeps inductance present at transient peak current.

    Copper loss at the rated current works out to roughly 0.641 W from a typical DCR of 5.3 mOhm at 11 A. It is the number to start a thermal stack-up with, before core loss and before AC resistance rise.

    Isat is specified as 20% rolloff @ +25 °C, so the number is a rolloff criterion rather than an absolute maximum. The useful working range extends a little beyond it on a soft saturation core, but the loop compensation has to be designed for the inductance that remains.

    Stored energy at Isat is about 33.8 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.

    K-factor 867 means the flux swing is about 408 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    Self-resonant frequency is 80 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.

    Where This Series Fits

    The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.

    In the HCM1A0503V2 line-up this part is number 5 of 15 by inductance, between 0.2 uH and 10 uH.

    One step down the table, HCM1A0503V2-R35-R, sits at 0.35 uH with 14 A and 2.9 mOhm – the lower inductance buys about 4 A of extra current in the same body.

    • Core material: alloy powder core, 5.7 x 5.4 mm body at 3.0 mm.
    • Typical applications: body electronics; central body control module; vehicle access control system; headlamps, tail lamps and interior lighting and led lighting; heating ventilation and air conditioning controllers (hvac); doors, window lift and seat control.
    • The +155 °C rating is ambient plus self-temperature rise. Derate against the hot DCR, not the +20 °C value, when the board sits in a warm enclosure.

    Design Notes

    Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 6.1 mOhm becomes roughly 9.34 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.

    • Check Isat and DCR at the hot corner, not at +20 °C.
    • Confirm the qualification file covers the module-level test plan.
    • Verify the qualification and the mounting process match the assembly line.

    Frequently Asked Questions

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    What is the operating temperature range?
    The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.

    Does the automotive grade change the electrical values?
    Not by itself, but it changes the qualification and often the temperature range. Compare the rows of the automotive data sheet against the commercial one rather than assuming they match.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products