| Parameter | Value |
|---|---|
| Orderable part number | HCM1A0503V3-1R5-R |
| OCL (open circuit inductance) | 1.5 uH ±20% |
| FLL minimum, at Isat | 0.96 uH |
| Irms (DC, 40 °C rise) | 6.2 A |
| Isat (20% rolloff @ +25 °C) | 8.5 A |
| DCR typical @ +20 °C | 15.4 mOhm |
| DCR maximum @ +20 °C | 17.7 mOhm |
| SRF typical | 40 MHz |
| K-factor (Bp-p = K x L x dI) | 418, Bp-p in Gauss |
| Package | 5.7 x 5.4 mm |
| Height | 3.0 mm |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +155 °C (ambient plus self-heating) |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data ELX1483 |

Drawing reproduced from Eaton Technical Data ELX1483: outline with
rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
the drawing itself.
Molded, shielded, AEC-Q200: the family is built for under-hood and in-cabin electronics where the ambient can reach 125 °C and the board cannot afford a radiating inductor. Soft saturation means the transient current does not disappear the inductance, and the shielding keeps the switching harmonics off nearby sensor wiring.
The DCR figure of 15.4 mOhm is what sets the efficiency: at 6.2 A the winding drops about 0.095 mV and dissipates 0.592 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.
The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.
At Isat the part holds about 54.2 uJ. On a multiphase rail that is the energy per phase available to bridge a load step, which sets how much bulk capacitance the controller still needs.
The K-factor of 418 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 627 Gauss of Bp-p, the figure the core-loss curve is plotted against.
Self-resonant frequency is 40 MHz typical. Above that the part becomes capacitive and stops behaving as an inductor, which is why the switching frequency and its first harmonics should stay well below it.
The HCM1A family is the automotive molded range: AEC-Q200 qualified, rated to +155 °C, from a 5 mm footprint up to a 22 mm body. Several sizes carry a V2 or V3 revision with a higher current rating or an extra saturation column, so the revision letter is part of the specification.
The HCM1A0503V3 family spans 0.2 uH to 10 uH; this row sits at position 9 of 15.
Compared with its neighbours in the table, HCM1A0503V3-2R2-R trades 2.9 A of rated current for the next inductance step, which is the usual compromise in this family.
Copper resistance rises with temperature, so at the +155 °C limit the maximum DCR of 17.7 mOhm becomes roughly 27.1 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.
Design note: the revision letter changes the electrical row. V2 and V3 parts of the same body size are not drop-in substitutes for the base part; compare the tables row by row.
What is the operating temperature range?
The rated range is quoted as ambient plus self-temperature rise, up to the maximum shown in the table. The part is qualified across that span, but the hot corner is where saturation and DCR must be checked.
What is the self-resonant frequency used for?
It marks the point where the winding capacitance dominates. Keep the switching frequency and the harmonics that carry energy below it, and use it to compare candidates of the same inductance.
Why do V2 and V3 parts exist?
They are later revisions of the same body size with a changed electrical row – typically a higher current rating or an extra parameter such as self-resonant frequency. They are separate orderable parts, not substitutes.